CVE-2025-10659 Megasys Enterprises CVE debrief

CVE-2025-10659 is a critical remote code execution issue in Megasys Enterprises Telenium Online Web Application. According to CISA’s advisory, an unauthenticated network attacker can send a crafted HTTP request to a vulnerable PHP endpoint and inject operating system commands because of improper handling of user input and insecure regular-expression termination. The result is remote code execution in the context of the web application service account. Megasys states that a fix is available.

Vendor
Megasys Enterprises
Product
Telenium Online Web Application
CVSS
CRITICAL 9.8
CISA KEV
Not listed in stored evidence
Original CVE published
2025-09-30
Original CVE updated
2025-09-30
Advisory published
2025-09-30
Advisory updated
2025-09-30

Who should care

Administrators and operators running Megasys Enterprises Telenium Online Web Application should treat this as urgent, especially any team exposing the application to untrusted networks. Security teams responsible for patch management, perimeter exposure review, and web-application hardening should prioritize validation and remediation immediately.

Technical summary

The advisory describes a PHP endpoint that is reachable by unauthenticated network users and does not correctly validate or sanitize attacker-controlled input. CISA says the vulnerability stems from insecure termination of a regular-expression check, which allows command injection through a crafted HTTP request. The stated impact is remote code execution on the server with the privileges of the web application service account. The provided CVSS vector is CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H, matching a network-reachable, no-authentication, high-impact flaw.

Defensive priority

Immediate. This is a network-exposed, unauthenticated RCE with critical impact and no user interaction required. If the affected application is reachable from any untrusted network, remediation should be treated as high priority and completed as soon as operationally possible.

Recommended defensive actions

  • Apply the Megasys-provided fix using the vendor support instructions.
  • Restrict network exposure to the Telenium Online Web Application until remediation is complete.
  • Review logs for unusual HTTP requests targeting the affected PHP endpoint.
  • Verify the application is running with the least-privilege service account possible.
  • After patching, validate that the vulnerable endpoint no longer accepts unexpected input paths or command-like payloads.
  • Track CISA and CVE references for any advisory updates or revised remediation guidance.

Evidence notes

CISA’s CSAF advisory for ICSA-25-273-01 states that the Telenium Online Web Application has a vulnerable PHP endpoint accessible to unauthenticated network users, that insecure termination of a regular-expression check allows arbitrary OS command injection, and that the result can be remote code execution in the context of the web application service account. The advisory also notes that Megasys Enterprises has provided a fix and directs users to the vendor support page for application instructions.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-10659 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-10659

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-10659 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-10659

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-273-01.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-273-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.