PatchSiren cyber security CVE debrief
CVE-2025-8769 MegaSys Computer Technologies CVE debrief
CVE-2025-8769 is a critical remote code execution vulnerability in the Telenium Online Web Application by MegaSys Computer Technologies. The vulnerability stems from improper input validation in a Perl script responsible for loading the login page, allowing attackers to inject arbitrary Perl code via crafted HTTP requests. This vulnerability was initially published on September 19, 2024, as ICSA-24-263-04 with CVE-2024-6404, then updated on August 12, 2025, to assign CVE-2025-8769. Affected versions include Telenium Online Web Application 8.3 and earlier. The CVSS 3.1 score of 9.8 reflects network attack vector, low attack complexity, no required privileges or user interaction, and high impact on confidentiality, integrity, and availability. MegaSys has released patched versions 7.4.72 and 8.3.36 to address this vulnerability. Organizations unable to immediately patch should consider disabling the web/browser-based interface as a temporary mitigation measure.
- Vendor
- MegaSys Computer Technologies
- Product
- Telenium Online Web Application
- CVSS
- CRITICAL 9.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-09-19
- Original CVE updated
- 2025-08-12
- Advisory published
- 2024-09-19
- Advisory updated
- 2025-08-12
Who should care
Organizations operating MegaSys Telenium Online Web Application for industrial control system management, particularly in critical infrastructure sectors. Security teams responsible for OT/ICS environments, web application security, and Perl-based application deployments should prioritize patching.
Technical summary
The Telenium Online Web Application contains a Perl script used to load the login page that fails to properly validate user-supplied input. An unauthenticated remote attacker can exploit this weakness by sending a crafted HTTP request containing malicious Perl code, which the server executes, resulting in full remote code execution. The vulnerability affects all versions up to and including 8.3. The attack requires no authentication, no user interaction, and can be executed over the network with low complexity.
Defensive priority
critical
Recommended defensive actions
- Apply vendor patches: upgrade to Telenium Online Web Application v7.4.72 or v8.3.36 as appropriate for your deployment.
- If immediate patching is not feasible, disable the web/browser-based interface to mitigate exposure.
- Restrict network access to the Telenium Online Web Application to authorized administrative hosts only.
- Monitor web application logs for anomalous HTTP requests targeting the login page or Perl script endpoints.
- Contact MegaSys Computer Technologies support for additional assistance with remediation.
Evidence notes
Vulnerability details sourced from CISA CSAF advisory ICSA-24-263-04. The advisory was initially published September 19, 2024, and updated August 12, 2025, to replace CVE-2024-6404 with CVE-2025-8769. Affected product confirmed as Telenium Online Web Application versions 8.3 and earlier. Vendor fixes confirmed as versions 7.4.72 and 8.3.36.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-8769 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-8769
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-8769 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-8769
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-263-04.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-263-04
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.