PatchSiren cyber security CVE debrief
CVE-2026-20556 MediaTek, Inc. CVE debrief
CVE-2026-20556 debrief based on the supplied source corpus. The vulnerability is a possible out of bounds write in Modem due to a missing bounds check, which could lead to remote escalation of privilege if a UE has connected to a rogue base station controlled by the attacker. Defenders should assess exposure and prioritize verification of affected versions and remediation guidance from official sources. This CVE record was published on 2026-11-02T03:17:32.697Z and has not been modified since then.
- Vendor
- MediaTek, Inc.
- Product
- MediaTek chipset
- CVSS
- Unknown
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-11-02
- Original CVE updated
- 2026-11-02
- Advisory published
- 2026-11-02
- Advisory updated
- 2026-11-02
Who should care
Defenders responsible for Modem or related systems should assess exposure and prioritize verification of affected versions and remediation guidance from official sources. This includes operators, platform administrators, vulnerability management teams, and security teams who need to review and apply patches or mitigations to prevent potential remote escalation of privilege. They should also review compensating controls for exposed systems while remediation
Why it matters
CVE-2026-20556 is a possible out of bounds write in Modem due to a missing bounds check. Defenders should prioritize verification of affected versions and remediation guidance from official sources to prevent potential remote escalation of privilege.
- Remote escalation of privilege possible if UE connects to rogue base station
- Requires verification of affected versions and systems
- Patch application recommended if available
Technical summary
A possible out of bounds write in Modem due to a missing bounds check could lead to remote escalation of privilege if a UE has connected to a rogue base station controlled by the attacker. This vulnerability affects Modem and could be exploited without additional execution privileges needed. User interaction is not needed for exploitation. The CVE record indicates that the Patch ID is MOLY01876662 and the Issue ID is MSV-9833. Defenders should prioritize verification of affected versions and remediation guidance from official sources.
Defensive priority
Defenders should prioritize verification of affected versions and remediation guidance from official sources.
Recommended defensive actions
- Verify affected versions and systems
- Review and apply patch if available
- Monitor for potential exploitation attempts
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
- Review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance
- Plan vendor-supported updates or mitigations through normal change control where exposure is confirmed
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
Evidence notes
The CVE record indicates a possible out of bounds write in Modem due to a missing bounds check, which could lead to remote escalation of privilege if a UE has connected to a rogue base station controlled by the attacker.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-20556 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-20556
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-20556 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-20556
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://www.mediatek.com/product-security-bulletin/November-2026
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.