PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-20506 MediaTek, Inc. CVE debrief

A use-after-free vulnerability exists in the Audio HAL component of MediaTek chipsets. This issue could lead to local escalation of privilege if a malicious actor has already obtained System privilege. User interaction is not required for exploitation. The vulnerability is identified by Patch ID: ALPS11191981 and Issue ID: MSV-9126. Defenders should assess exposure and apply patches to mitigate potential risks. The CVE record and NVD entry provide additional details on the vulnerability.

Vendor
MediaTek, Inc.
Product
MediaTek chipset
CVSS
MEDIUM 6.7
CISA KEV
Not listed in stored evidence
Original CVE published
2026-09-07
Original CVE updated
2026-09-08
Advisory published
2026-09-07
Advisory updated
2026-09-08

Who should care

Defenders responsible for MediaTek chipset deployments should assess exposure and apply patches. Security teams and vulnerability management teams should review the CVE record and NVD entry for additional details. Operators and administrators of affected MediaTek chipsets should verify System privilege requirements and review compensating controls. IT teams and incident response teams should be aware of the potential risks and plan for remediation.

Why it matters

CVE-2026-20506 is a use-after-free vulnerability in MediaTek Audio HAL that could lead to local escalation of privilege. Defenders should assess exposure, apply patches, and verify System privilege requirements.

  • Local escalation of privilege requires System privilege
  • No user interaction needed for exploitation
  • Patch available for affected MediaTek chipsets

Technical summary

The Audio HAL component of MediaTek chipsets contains a use-after-free vulnerability. This issue could lead to local escalation of privilege if a malicious actor has already obtained System privilege. The vulnerability is identified by Patch ID: ALPS11191981 and Issue ID: MSV-9126. User interaction is not required for exploitation. The CVE record and NVD entry provide additional technical details on the vulnerability. Defenders should assess exposure and apply patches to mitigate potential risks. The vulnerability affects MediaTek chipsets and requires System privilege for exploitation.

Defensive priority

Assess exposure and apply patch

Recommended defensive actions

  • Assess exposure of MediaTek chipsets in your environment
  • Apply patch identified by Patch ID: ALPS11191981
  • Verify System privilege requirements for affected components
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and NVD entry provide details on the vulnerability. A patch is available, identified by Patch ID: ALPS11191981. The vulnerability affects MediaTek chipsets and could lead to local escalation of privilege. User interaction is not needed for exploitation. Defenders should verify System privilege requirements for affected components and assess exposure.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-20506 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-20506

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-20506 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-20506

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.