PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-86299 Linksys CVE debrief

A vulnerability was detected in Linksys RE7000 2.0.15. This affects the function platform_event_pingTest of the file /cgi-bin/json.cgi?PingTest of the component PingTest Handler. The manipulation of the argument pingTestIp/pingTestPktSize/pingTestTimes results in os command injection. The attack can be launched remotely. The exploit is now public and may be used.

Vendor
Linksys
Product
RE7000
CVSS
HIGH 8.6
CISA KEV
Not listed in stored evidence
Original CVE published
2026-09-07
Original CVE updated
2026-09-11
Advisory published
2026-09-07
Advisory updated
2026-09-11

Who should care

Defenders responsible for Linksys RE7000 devices should assess exposure and potential impact on their network. This includes verifying device configurations, reviewing network operations, and prioritizing patching or mitigation efforts. Security teams and vulnerability management teams should also be aware of this vulnerability and its potential impact on their assets.

Why it matters

This vulnerability allows for OS command injection, which can lead to unauthorized access and control of affected devices.

  • Verify exposure of Linksys RE7000 devices to this vulnerability
  • Assess potential impact on network operations
  • Prioritize patching or mitigation efforts

Technical summary

The vulnerability affects the PingTest Handler component of Linksys RE7000 2.0.15, allowing for OS command injection through manipulation of the pingTestIp, pingTestPktSize, and pingTestTimes arguments. This can lead to unauthorized access and control of affected devices. The vulnerability has a CVSS score of 8.6 and is considered HIGH severity. Defenders should prioritize verifying exposure and assessing potential impact on their network. The exploit is now public and may be used, emphasizing the need for prompt action.

Defensive priority

Defenders should prioritize verifying exposure of Linksys RE7000 devices to this vulnerability and assessing the potential impact on their network.

Recommended defensive actions

  • Verify exposure of Linksys RE7000 devices to this vulnerability
  • Assess the potential impact on the network
  • Consider applying patches or mitigations provided by the vendor
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and NVD entry provide details on the vulnerability, including its description, CVSS score, and affected product. The vulnerability affects Linksys RE7000 2.0.15 devices. Defenders should verify exposure and assess potential impact. The exploit is public and may be used. Evidence limits suggest verifying device configurations and network exposure.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-86299 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-86299

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-86299 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-86299

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.