PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-109352 librenms CVE debrief

LibreNMS before 26.9.0 contains a stored cross-site scripting vulnerability in includes/html/pages/device/wireless.inc.php, which echoes wireless sensor sensor_descr values, populated from SNMP DisplayString fields during discovery, into HTML without escaping. Attackers controlling a monitored device's SNMP agent can set values such as AI-AP-MIB::aiSSID to malicious JavaScript that executes when authenticated users view the device's Wireless tab, enabling session hijacking.

Vendor
librenms
Product
Unknown
CVSS
MEDIUM 5.3
CISA KEV
Not listed in stored evidence
Original CVE published
2026-10-12
Original CVE updated
2026-10-12
Advisory published
2026-10-12
Advisory updated
2026-10-12

Who should care

Defenders responsible for LibreNMS installations, particularly those with wireless sensor configurations, should assess exposure and prioritize verification and updates. This includes reviewing configurations, monitoring for suspicious activity, and ensuring timely updates to prevent exploitation. Security teams and vulnerability management teams should also be aware of the potential risks and take appropriate measures.

Why it matters

CVE-2026-109352 is a stored cross-site scripting vulnerability in LibreNMS before 26.9.0 that allows attackers to execute malicious JavaScript, enabling session hijacking. Defenders should prioritize verification and updates, and monitor wireless sensor configurations.

  • Session hijacking via malicious JavaScript execution
  • Potential for attackers to gain unauthorized access to user sessions
  • Need for defenders to verify and update LibreNMS installations
  • Importance of monitoring wireless sensor configurations for suspicious activity

Technical summary

The vulnerability is located in the includes/html/pages/device/wireless.inc.php file of LibreNMS before 26.9.0. It allows attackers controlling a monitored device's SNMP agent to set malicious JavaScript values, such as AI-AP-MIB::aiSSID, which execute when authenticated users view the device's Wireless tab, enabling session hijacking. This issue arises from the lack of proper escaping of user-supplied input. The vulnerability can be exploited by setting malicious values via SNMP, which are then stored and executed as part of the device's Wireless tab.

Defensive priority

Defenders should prioritize verifying and updating LibreNMS installations to version 26.9.0 or later, and review wireless sensor configurations for potential malicious modifications.

Recommended defensive actions

  • Verify and update LibreNMS installations to version 26.9.0 or later
  • Review wireless sensor configurations for potential malicious modifications
  • Monitor for suspicious activity on the Wireless tab
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
  • Review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance

Evidence notes

The CVE record and source item provide details on the vulnerability, including its location in the wireless.inc.php file and the potential impact of session hijacking. The vulnerability is located in the includes/html/pages/device/wireless.inc.php file of LibreNMS before 26.9.0. Attackers controlling a monitored device's SNMP agent can set values such as AI-AP-MIB::aiSSID to malicious JavaScript that executes when authenticated users view the device's Wireless tab, enabling session hijacking. Evidence is limited to public CVE Program,

Sources and references

Verified primary and authoritative sources

  • CVE-2026-109352 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-109352

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-109352 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-109352

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • LibreNMS before 26.9.0 Stored XSS via wireless sensor description

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/109xxx/CVE-2026-109352.json

    cve_program_cvelist_v5

  • Source reference

    Unverified legacy reference

    URL: https://github.com/librenms/librenms/security/advisories/GHSA-ffjc-4fr5-47c6

    Supplemental source - vendor-advisory