PatchSiren cyber security CVE debrief
CVE-2026-111654 kerwincui CVE debrief
CVE-2026-111654 is a vulnerability in FastBee through version 2.1.0, which allows authenticated low-privilege users to access other users' device groups due to insecure direct object references in the GroupController queries. This could enable attackers, including self-registered users, to read, overwrite, reassign, rewrite device associations of, or delete other users' groups by supplying sequential group IDs.
- Vendor
- kerwincui
- Product
- FastBee
- CVSS
- MEDIUM 5.3
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-16
- Original CVE updated
- 2026-10-21
- Advisory published
- 2026-10-16
- Advisory updated
- 2026-10-21
Who should care
Defenders responsible for securing FastBee deployments should assess exposure and prioritize verification and remediation efforts. This includes reviewing and securing the GroupController and related components, implementing proper authorization checks, and monitoring access to device groups.
Why it matters
CVE-2026-111654 is a medium-severity vulnerability in FastBee that allows authenticated low-privilege users to access other users' device groups, potentially leading to unauthorized access, modification, or deletion of device groups.
- Defenders need to verify and secure the GroupController to prevent unauthorized access to device groups.
- Implementing proper authorization checks is crucial to ensure only authorized users can access and modify device groups.
- Monitoring and auditing access to device groups is necessary to detect and respond to potential security incidents.
Technical summary
The vulnerability is caused by insecure direct object references in the GroupController queries, which allow authenticated low-privilege users to access other users' device groups. This could enable attackers to read, overwrite, reassign, rewrite device associations of, or delete other users' groups by supplying sequential group IDs. The affected product, FastBee, is used in IoT deployments, and defenders should prioritize verifying and securing the GroupController and related components to prevent unauthorized access to device groups. Implementing proper authorization checks is crucial to ensure only authorized users can access and modify device groups.
Defensive priority
Defenders should prioritize verifying and securing the GroupController and related components to prevent unauthorized access to device groups.
Recommended defensive actions
- Verify and secure the GroupController and related components to prevent unauthorized access to device groups.
- Implement proper authorization checks to ensure only authorized users can access and modify device groups.
- Monitor and audit access to device groups to detect and respond to potential security incidents.
- Review compensating controls for exposed systems while remediation is scheduled and verified.
- Check relevant monitoring, detection, and logs for exposed assets that need extra review.
- Track exceptions, retest remediated assets, and close the item only after evidence is documented.
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up.
Evidence notes
The vulnerability is confirmed in FastBee version 2.1.0 and earlier, based on official CVE Program and NVD records. The GroupController queries lack owner checks, allowing authenticated low-privilege users to access other users' device groups by supplying sequential group IDs. Defenders should verify and secure the GroupController and related components, implementing proper authorization checks and monitoring access to device groups. Evidence is limited to public CVE details and NVD assessments; further verification is needed to fully
Sources and references
Verified primary and authoritative sources
-
CVE-2026-111654 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-111654
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-111654 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-111654
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
FastBee through 2.1.0 IDOR via /iot/group By-ID Endpoints
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/111xxx/CVE-2026-111654.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://hackmd.io/@hieuPenguinnn/fastbee-device-group-cross-user-idor
Supplemental source - third-party-advisory
-
Source reference
Unverified legacy reference
URL: https://github.com/kerwincui/FastBee/blob/v2.1.0/springboot/fastbee-open-api/src/main/java/com/fastbee/data/controller/GroupController.java
Supplemental source - technical-description
-
Source reference
Unverified legacy reference
URL: https://github.com/kerwincui/FastBee/blob/v2.1.0/springboot/fastbee-service/fastbee-iot-service/src/main/java/com/fastbee/iot/service/impl/GroupServiceImpl.java
Supplemental source - technical-description
-
Source reference
Unverified legacy reference
URL: https://github.com/kerwincui/FastBee/blob/v2.1.0/springboot/fastbee-service/fastbee-iot-service/src/main/resources/mapper/iot/GroupMapper.xml
Supplemental source - technical-description
-
Source reference
Unverified legacy reference
URL: https://www.vulncheck.com/advisories/fastbee-through-2.1.0-idor-via-iot-group-by-id-endpoints
Supplemental source - third-party-advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.