PatchSiren cyber security CVE debrief
CVE-2026-101946 Juniper Networks CVE debrief
AI-assisted PatchSiren debrief based on the supplied source corpus. The CVE record was published on 2026-10-14T16:42:54.291Z and has not been modified since then. CVE-2026-101946 is a low-severity vulnerability in Junos OS and Junos OS Evolved that can lead to limited memory disclosure and LDP adjacency disruption. Network administrators and security teams should assess exposure and prioritize verification. The vulnerability is caused by an Out-of-bounds Read in the rpd process, allowing an adjacent low-privilege attacker to disclose limited rpd process memory and disrupt an LDP adjacency via an IPv6 LDP message.
- Vendor
- Juniper Networks
- Product
- Junos OS
- CVSS
- LOW 3.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-14
- Original CVE updated
- 2026-10-16
- Advisory published
- 2026-10-14
- Advisory updated
- 2026-10-16
Who should care
Network administrators and security teams responsible for Junos OS and Junos OS Evolved deployments should assess exposure and prioritize verification.
Why it matters
CVE-2026-101946 is a low-severity vulnerability in Junos OS and Junos OS Evolved that can lead to limited memory disclosure and LDP adjacency disruption. Network administrators and security teams should assess exposure, prioritize verification, and apply patches or updates as needed.
- Potential disclosure of limited rpd process memory
- Disruption of LDP adjacency via IPv6 LDP message
- Verification of Junos OS and Junos OS Evolved versions for potential exposure
- Prioritization of patching or updating vulnerable deployments
Technical summary
An Out-of-bounds Read vulnerability in the rpd process of Juniper Networks Junos OS and Junos OS Evolved allows an adjacent low-privilege attacker to disclose limited rpd process memory and disrupt an LDP adjacency via an IPv6 LDP message. The vulnerability affects Junos OS and Junos OS Evolved deployments using IPv6 LDP. Network administrators and security teams should assess exposure, prioritize verification, and apply patches or updates as needed. The CVE record and source item provide details on the vulnerability, but limited information is available on the r
Defensive priority
Network administrators and security teams should assess exposure and prioritize verification of Junos OS and Junos OS Evolved deployments using IPv6 LDP.
Recommended defensive actions
- Verify Junos OS and Junos OS Evolved versions for potential exposure
- Assess network configurations for IPv6 LDP usage
- Review and apply vendor-provided patches or updates
Evidence notes
The CVE record and source item provide details on the Out-of-bounds Read vulnerability in the rpd process of Juniper Networks Junos OS and Junos OS Evolved. Limited information is available on potential exploitation or impact.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-101946 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-101946
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-101946 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-101946
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Junos OS and Junos OS Evolved: An attacker causes rpd process memory disclosure when IPv6 LDP is
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/101xxx/CVE-2026-101946.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://supportportal.juniper.net/JSA112187
Supplemental source - vendor-advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.