PatchSiren cyber security CVE debrief
CVE-2026-64892 Johnson Controls CVE debrief
A vulnerability exists in Johnson Controls EasyIO Neo Series EC and CW Controllers, which could allow an attacker to gain access to sensitive information that could be used to conduct further attacks against the system. The affected products are EasyIO Neo Series EC Controllers: V3.3b63, V3.3b62, and EasyIO Neo Series CW Controllers: V3.3b25, V3.3b24. Defenders should prioritize verifying exposure of building automation and control systems, especially those using EasyIO Neo Series EC and CW Controllers, and assess the need for updates or mitigations.
- Vendor
- Johnson Controls
- Product
- EasyIO Neo Series EC Controllers
- CVSS
- LOW 3.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-01
- Original CVE updated
- 2026-10-01
- Advisory published
- 2026-10-01
- Advisory updated
- 2026-10-01
Who should care
Defenders responsible for building automation and control systems using EasyIO Neo Series EC and CW Controllers should assess exposure and prioritize updates or mitigations. This includes operators, platform administrators, vulnerability management teams, and security teams who need to verify exposure and implement recommended mitigations to reduce risk.
Why it matters
The vulnerability in Johnson Controls EasyIO Neo Series EC and CW Controllers could allow attackers to gain access to sensitive information, which could be used to conduct further attacks against the system. Defenders should prioritize verifying exposure and assessing the need for updates or mitigations.
- Verify exposure of building automation and control systems
- Assess the need for updates or mitigations to prevent potential attacks
- Implement recommended mitigations to reduce risk
Technical summary
The vulnerability exists in Johnson Controls EasyIO Neo Series EC and CW Controllers, which could allow an attacker to gain access to sensitive information. The affected products are EasyIO Neo Series EC Controllers: V3.3b63, V3.3b62, and EasyIO Neo Series CW Controllers: V3.3b25, V3.3b24. Defenders should prioritize verifying exposure of building automation and control systems, especially those using EasyIO Neo Series EC and CW Controllers, and assess the need for updates or mitigations to prevent potential attacks.
Defensive priority
Defenders should prioritize verifying exposure of building automation and control systems, especially those using EasyIO Neo Series EC and CW Controllers, and assess the need for updates or mitigations.
Recommended defensive actions
- Verify exposure of EasyIO Neo Series EC and CW Controllers in building automation and control systems
- Assess the need for updates to fixed versions (EC firmware V3.3b64 and CW firmware V3.3b26)
- Implement recommended mitigations, such as physical access controls and monitoring network traffic
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
Evidence notes
The source corpus provides details about the vulnerability and affected products, but limited information on exploitation or impact. Defenders should verify the exposure of building automation and control systems using EasyIO Neo Series EC and CW Controllers and assess the need for updates or mitigations. The source item provides details about the vulnerability and affected products.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-64892 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-64892
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-64892 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-64892
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Johnson Controls EasyIO Neo Series EC and CW Controllers
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-274-04.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-274-04
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.johnsoncontrols.com/trust-center/cybersecurity/resources
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.