PatchSiren cyber security CVE debrief
CVE-2024-7941 Hitachi Energy CVE debrief
CVE-2024-7941 is a medium-severity open redirect vulnerability in Hitachi Energy MicroSCADA Pro/X SYS600, published 2024-08-27 and last modified 2025-03-25. An HTTP parameter containing a URL value can cause the web application to redirect requests to attacker-specified URLs, enabling phishing attacks and credential theft. The vulnerability affects MicroSCADA X SYS600 version 10.5. Hitachi Energy released patches in January 2025 for versions 10.3, 10.4, and 10.5, with version 10.6 also available as a fixed release. CISA issued advisory ICSA-24-331-04 with recommended mitigations.
- Vendor
- Hitachi Energy
- Product
- MicroSCADA Pro/X SYS600
- CVSS
- MEDIUM 4.3
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2024-08-27
- Original CVE updated
- 2025-03-25
- Advisory published
- 2024-08-27
- Advisory updated
- 2025-03-25
Who should care
Organizations operating Hitachi Energy MicroSCADA X SYS600 version 10.5 or earlier in industrial control environments, particularly those with web-accessible SCADA interfaces. Security teams responsible for OT/ICS infrastructure, network administrators managing SCADA deployments, and compliance officers tracking CISA ICS advisories should prioritize assessment and patching.
Technical summary
The vulnerability exists in the web application component of MicroSCADA Pro/X SYS600 where an HTTP parameter accepts URL values without proper validation. An attacker can craft a request with a malicious URL in this parameter, causing the application to redirect the user's browser to an attacker-controlled site. This enables phishing attacks where users may be presented with fake login pages to harvest credentials. The attack requires user interaction (clicking a crafted link) and network access to the web interface. CVSS 3.1 score 4.3 (MEDIUM) reflects the need for user interaction and limited impact scope.
Defensive priority
medium
Recommended defensive actions
- Apply vendor patches: Update MicroSCADA X SYS600 to version 10.5 vulnerability patch 2025_01 or upgrade to version 10.6
- Implement network segmentation to limit exposure of SCADA web interfaces
- Configure web application firewalls to filter malicious redirect parameters
- Review and apply CISA ICS recommended practices for defense-in-depth
- Monitor for suspicious redirect requests in web access logs
- Educate users on phishing risks and verify URLs before entering credentials
Evidence notes
CVE published 2024-08-27; CISA advisory ICSA-24-331-04 issued same day. Advisory updated 2024-08-30 for CWE updates, 2024-10-29 for affected products and vulnerability details, and 2025-03-25 to add patches for versions 10.3, 10.4, and 10.5. CVSS 4.3 (MEDIUM) per source. Not listed in CISA KEV.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-7941 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-7941
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-7941 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-7941
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-331-04.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-24-331-04
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.