CVE-2024-7940 Hitachi Energy CVE debrief

CVE-2024-7940 is a High-severity Hitachi Energy MACH GWS issue disclosed by CISA on 2025-02-25. The advisory says a service intended for local-only access was exposed to all network interfaces without authentication. Hitachi Energy identifies MACH GWS versions 3.1.0.0 through 3.3.0.0 as affected and recommends upgrading to 3.4.0.0 or coordinating mitigation options with the local account team.

Vendor
Hitachi Energy
Product
MACH GWS
CVSS
HIGH 8.3
CISA KEV
Not listed in stored evidence
Original CVE published
2025-02-25
Original CVE updated
2025-02-25
Advisory published
2025-02-25
Advisory updated
2025-02-25

Who should care

Operators, administrators, and asset owners using Hitachi Energy MACH GWS, especially in operational technology or industrial environments where the service may be reachable from the network. Any organization running affected versions should treat this as a priority exposure because the vulnerable service is intended to be local-only but is exposed without authentication.

Technical summary

The CSAF advisory describes a network-exposed service that should have remained local-only and is accessible on all network interfaces without authentication. The provided CVSS vector is CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H, yielding a score of 8.3 (High). CISA lists affected products as Hitachi Energy MACH GWS versions 3.1.0.0 to 3.3.0.0 and the vendor remediation as upgrading to 3.4.0.0, with additional mitigation guidance available from the local account team.

Defensive priority

High. This is a remotely reachable exposure with no authentication on an intended local-only service, and the vendor has a fixed release. Prioritize identifying whether MACH GWS is deployed, determining exposure, and planning remediation or compensating controls.

Recommended defensive actions

  • Inventory all Hitachi Energy MACH GWS deployments and confirm whether any systems run versions 3.1.0.0 through 3.3.0.0.
  • Check whether the service is reachable from any non-local network path and restrict exposure immediately where possible.
  • Upgrade affected systems to version 3.4.0.0 per the vendor remediation guidance.
  • If immediate upgrading is not possible, contact the local account team for mitigation strategies as referenced in the advisory.
  • Review OT/ICS network segmentation and access controls to ensure local-only services are not broadly reachable.
  • Validate remediation after changes by confirming the affected service is no longer exposed beyond intended local access.

Evidence notes

All factual claims in this debrief are drawn from the supplied CSAF advisory metadata and associated official references. The advisory states the issue is that MACH GWS exposes a local-only service to all network interfaces without authentication, affects versions 3.1.0.0 to 3.3.0.0, and recommends upgrading to 3.4.0.0 or seeking mitigation guidance. The published and modified dates supplied for the CVE and source are 2025-02-25T13:30:00.000Z.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-7940 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-7940

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-7940 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-7940

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-133-03.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-133-03

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Reference

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.