PatchSiren

PatchSiren cyber security CVE debrief

CVE-2024-2011 Hitachi Energy CVE debrief

CVE-2024-2011 affects Hitachi Energy UNEM and is described as a heap-based buffer overflow that can generally lead to denial of service and may also allow arbitrary code execution. The supplied corpus rates the issue HIGH (CVSS 8.6) and shows it impacts multiple UNEM releases, including R16B PC2, R15B PC4, R16A, R15A, and versions older than R15A. Vendor guidance indicates a fix path for some branches and no remediation planned for EOL versions, so operators should treat this as a high-priority OT patching and mitigation item.

Vendor
Hitachi Energy
Product
UNEM
CVSS
HIGH 8.6
CISA KEV
Not listed in stored evidence
Original CVE published
2024-06-11
Original CVE updated
2024-10-29
Advisory published
2024-06-11
Advisory updated
2024-10-29

Who should care

OT/ICS operators running Hitachi Energy UNEM, plant and substation administrators, industrial control system security teams, vulnerability managers, and anyone responsible for patching or segmenting affected UNEM deployments.

Technical summary

The issue is a heap-based buffer overflow in UNEM. The supplied CVSS vector is CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H, which indicates network reachability, low attack complexity, no privileges, and no user interaction. The primary expected impact is denial of service, but the advisory also states arbitrary code execution is possible. Affected product entries include UNEM R16B PC2, R15B PC4, R16A, R15A, and older than R15A; remediation notes list fixes for R16B PC3 with a recommendation to move to R16B PC4, and R15B PC5 under development.

Defensive priority

High — prioritize patching and exposure reduction for affected UNEM instances, especially any systems reachable from less-trusted networks or supporting critical operations.

Recommended defensive actions

  • Confirm which UNEM releases are in use and map them against the affected product list: R16B PC2, R15B PC4, R16A, R15A, and versions older than R15A.
  • Apply the vendor-recommended upgrade path: move supported R16B systems to PC4; for the R15B branch, plan for PC5 when available and follow vendor mitigation guidance.
  • For EOL versions with no fix planned, accelerate migration to a supported release because the advisory states no remediation will be provided for those versions.
  • Use CISA ICS defense-in-depth and recommended practices to reduce exposure, including restricting network access and segmenting OT environments from untrusted networks.
  • Monitor UNEM systems for instability or unexpected service interruption and validate backups and recovery procedures before making changes.

Evidence notes

The corpus ties this CVE to Hitachi Energy UNEM through the CISA CSAF advisory metadata and vendor references. The vulnerability description explicitly states heap-based buffer overflow with denial-of-service impact and possible arbitrary code execution. The supplied CVSS vector is AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H, supporting a network-exploitable, low-complexity issue with high availability impact. Remediation notes distinguish between fixed, planned, and end-of-life product branches. No KEV entry or ransomware association is supplied in the corpus.

Sources and references

Verified primary and authoritative sources

  • CVE-2024-2011 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2024-2011

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2024-2011 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2024-2011

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source item URL

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-030-01.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-030-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf

    Reference

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Reference