PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-8991 glenwpcoder CVE debrief

The Drag and Drop Multiple File Upload for Contact Form 7 plugin for WordPress is vulnerable to Stored Cross-Site Scripting via 'drag_n_drop_text' and 'drag_n_drop_browse_text' Settings in all versions up to, and including, 1.3.9.7 due to insufficient input sanitization and output escaping. This makes it possible for authenticated attackers, with administrator-level access and above, to inject arbitrary web scripts in pages that will execute whenever a user accesses an injected page.

Vendor
glenwpcoder
Product
Drag and Drop Multiple File Upload for Contact Form 7
CVSS
MEDIUM 4.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-06-06
Original CVE updated
2026-07-23
Advisory published
2026-06-06
Advisory updated
2026-07-23

Who should care

Users of the Drag and Drop Multiple File Upload for Contact Form 7 plugin for WordPress, particularly those with administrator-level access and above.

Technical summary

The vulnerability exists in the Drag and Drop Multiple File Upload for Contact Form 7 plugin for WordPress, affecting all versions up to and including 1.3.9.7. It is caused by insufficient input sanitization and output escaping in the 'drag_n_drop_text' and 'drag_n_drop_browse_text' settings. This allows authenticated attackers with administrator-level access and above to inject arbitrary web scripts into pages, which will execute when a user accesses the injected page.

Defensive priority

MEDIUM

Recommended defensive actions

  • Update the Drag and Drop Multiple File Upload for Contact Form 7 plugin to a version beyond 1.3.9.7.
  • Restrict administrator-level access and above to trusted users only.
  • Monitor pages for injected scripts.

Evidence notes

The CVE-2026-8991 record and associated details were obtained from official sources.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-8991 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-8991

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-8991 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-8991

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source reference

    Unverified legacy reference

    URL: https://plugins.trac.wordpress.org/browser/drag-and-drop-multiple-file-upload-contact-form-7/tags/1.3.9.6/assets/js/codedropz-uploader-min.js

    [email protected]

  • Source reference

    Unverified legacy reference

    URL: https://plugins.trac.wordpress.org/browser/drag-and-drop-multiple-file-upload-contact-form-7/tags/1.3.9.6/inc/dnd-upload-cf7.php

    [email protected]

  • Source reference

    Unverified legacy reference

    URL: https://plugins.trac.wordpress.org/browser/drag-and-drop-multiple-file-upload-contact-form-7/tags/1.3.9.6/inc/dnd-upload-cf7.php

    [email protected]

  • Source reference

    Unverified legacy reference

    URL: https://plugins.trac.wordpress.org/browser/drag-and-drop-multiple-file-upload-contact-form-7/tags/1.3.9.7/assets/js/codedropz-uploader-min.js

    [email protected]

  • Source reference

    Unverified legacy reference

    URL: https://plugins.trac.wordpress.org/browser/drag-and-drop-multiple-file-upload-contact-form-7/tags/1.3.9.7/inc/dnd-upload-cf7.php

    [email protected]

  • Source reference

    Unverified legacy reference

    URL: https://plugins.trac.wordpress.org/browser/drag-and-drop-multiple-file-upload-contact-form-7/tags/1.3.9.7/inc/dnd-upload-cf7.php

    [email protected]

Methodology and review provenance