PatchSiren cyber security CVE debrief
CVE-2026-67578 FURUNO ELECTRIC CO.,LTD. CVE debrief
The FURUNO FA-50 Class B AIS Transponder has a vulnerability where some configurations can be changed on the management screen without authentication. This issue has a CVSS score of 7.5 and is considered HIGH severity. The product's production ended in October 2020, and software updates are no longer provided. Defenders should verify exposure and assess potential impact on vessel management and control. The vulnerability allows unauthorized configuration changes, posing a risk to vessel management and control. It is essential to prioritize verification of exposure and assess potential impact.
- Vendor
- FURUNO ELECTRIC CO.,LTD.
- Product
- FURUNO FA-50 Class B AIS Transponder
- CVSS
- HIGH 7.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-08-25
- Original CVE updated
- 2026-08-25
- Advisory published
- 2026-08-25
- Advisory updated
- 2026-08-25
Who should care
Defenders responsible for industrial control systems, particularly those using FURUNO FA-50 Class B AIS Transponders, should assess exposure and verify configurations. They should also prioritize verification of exposure and assess potential impact on vessel management and control. Additionally, defenders should review vendor guidance and conduct vulnerability scanning for FA-50 Class B AIS Transponders.
Why it matters
The FURUNO FA-50 Class B AIS Transponder vulnerability allows unauthorized configuration changes, posing a risk to vessel management and control. Defenders should prioritize verification of exposure and assess potential impact.
- Verify exposure of FA-50 Class B AIS Transponders in inventory
- Assess impact of configuration changes on vessel management
- Implement compensating controls to prevent unauthorized access
Technical summary
The FURUNO FA-50 Class B AIS Transponder has a vulnerability where some configurations can be changed on the management screen without authentication. The product's production ended in October 2020, and software updates are no longer provided. This vulnerability allows unauthorized configuration changes, which can impact vessel management and control. Defenders should prioritize verifying exposure of FA-50 Class B AIS Transponders in their inventory, especially those directly connected to the internet, and assess the impact of configuration changes. The vulnerability has a CVSS score of 7.5 and is considered HIGH severity.
Defensive priority
Defenders should prioritize verifying exposure of FA-50 Class B AIS Transponders in their inventory, especially those directly connected to the internet, and assess the impact of configuration changes.
Recommended defensive actions
- Verify FA-50 Class B AIS Transponder inventory and configurations
- Assess exposure and potential impact of configuration changes
- Implement compensating controls to prevent unauthorized access
- Review vendor guidance for FA-50 Class B AIS Transponder
- Conduct vulnerability scanning for FA-50 Class B AIS Transponders
- Monitor for suspicious activity on FA-50 Class B AIS Transponders
- Track changes to FA-50 Class B AIS Transponder configurations
Evidence notes
The source corpus provides limited information on affected versions and remediation. FURUNO ELECTRIC CO.,LTD. notes that production of this product ended in October 2020, and software updates will no longer be provided.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-67578 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-67578
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-67578 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-67578
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
FURUNO FA-50 Class B AIS Transponder
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-237-07.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://jvn.jp/en/vu/JVNVU95422936/
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-07
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.