PatchSiren cyber security CVE debrief
CVE-2026-59769 FURUNO ELECTRIC CO.,LTD. CVE debrief
PatchSiren debrief for CVE-2026-59769: An attacker with credentials and in-vessel network access can alter device settings on the FURUNO FA-50 Class B AIS Transponder. This critical vulnerability has a CVSS score of 9.1. FURUNO notes that production ended in October 2020, and software updates are no longer provided. The vulnerability allows unauthorized setting changes, posing significant risks to vessel network security. Defenders should assess exposure and implement compensating controls.
- Vendor
- FURUNO ELECTRIC CO.,LTD.
- Product
- FURUNO FA-50 Class B AIS Transponder
- CVSS
- CRITICAL 9.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-08-25
- Original CVE updated
- 2026-08-25
- Advisory published
- 2026-08-25
- Advisory updated
- 2026-08-25
Who should care
Defenders of vessel networks, particularly those using FURUNO FA-50 Class B AIS Transponders, should assess exposure and implement compensating controls. This includes verifying the presence of FA-50 devices in their networks, restricting access to settings screens, and monitoring for signs of compromise or unauthorized changes. Additionally, security teams should prioritize patching or mitigating this vulnerability due to its critical severity and the end
Why it matters
CVE-2026-59769 is a critical vulnerability in the FURUNO FA-50 Class B AIS Transponder that allows unauthorized setting changes. Defenders of vessel networks should assess exposure, restrict access, and monitor for unauthorized changes. Production of the device ended in October 2020, and software updates are no longer provided, increasing the need for compensating controls.
- Verify exposure of FA-50 devices in vessel networks
- Restrict access to settings screens to prevent unauthorized changes
- Monitor for signs of compromise or unauthorized changes
- Implement compensating controls for unsupported devices
Technical summary
The FURUNO FA-50 Class B AIS Transponder is vulnerable to unauthorized setting changes. An attacker with credentials and access to the in-vessel network can alter device settings. The device's production ended in October 2020, and software updates are no longer provided. This critical vulnerability has a CVSS score of 9.1, emphasizing the need for immediate assessment and mitigation by defenders of vessel networks. The vulnerability class involves improper access control, allowing attackers to modify settings without authorization.
Defensive priority
Verify exposure of FA-50 devices in vessel networks, restrict access to settings screens, and monitor for unauthorized changes.
Recommended defensive actions
- Verify exposure of FA-50 devices in vessel networks
- Restrict access to settings screens
- Monitor for unauthorized changes
- Implement compensating controls for unsupported devices
- Review vendor guidance for potential mitigations
- Conduct an asset inventory of FA-50 devices
- Track changes to FA-50 device configurations
Evidence notes
The source corpus provides details on the vulnerability and its impact, noting that production of the device ended in October 2020 and software updates are no longer provided. The CVE record was published on 2026-08-25T06:00:00.000Z and has not been modified since then. Evidence is limited to the information provided by the source item and CVE Program record.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-59769 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-59769
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-59769 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-59769
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
FURUNO FA-50 Class B AIS Transponder
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-237-07.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://jvn.jp/en/vu/JVNVU95422936/
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-07
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-alerts/ics-alert-10-301-01
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.