PatchSiren cyber security CVE debrief
CVE-2026-37458 FRRouting CVE debrief
CVE-2026-37458 is a Denial of Service (DoS) vulnerability in FRRouting (FRR) stable/10.0 to stable/10.6 due to missing input validation in the MP_REACH_NLRI component. Authenticated attackers can cause a DoS by supplying a crafted UPDATE message. This vulnerability has a medium severity and requires immediate attention from network administrators and defenders responsible for FRRouting systems to assess exposure and prioritize patching. The CVE record and NVD entry provide details on the vulnerability, including its description, CVSS score, and affected versions. However, specific exploitation instances or additional remediation steps beyond patching are not established in the CVE.
- Vendor
- FRRouting
- Product
- FRR
- CVSS
- MEDIUM 6.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-05-04
- Original CVE updated
- 2026-11-11
- Advisory published
- 2026-05-04
- Advisory updated
- 2026-11-11
Who should care
Network administrators and defenders responsible for FRRouting systems should assess exposure and prioritize patching to prevent potential DoS attacks.
Why it matters
CVE-2026-37458 is a medium-severity Denial of Service vulnerability in FRRouting versions 10.0 to 10.6. Defenders should prioritize patching, inventory checks, and monitoring to mitigate potential DoS attacks. The corpus does not establish specific exploitation instances or remediation beyond patching.
- Potential Denial of Service (DoS) attacks against FRRouting systems
- Need for verification and application of patches for versions 10.0 to 10.6
- Importance of monitoring network traffic for suspicious UPDATE messages
- Potential impact on network availability and reliability
Technical summary
The MP_REACH_NLRI component of FRRouting (FRR) stable/10.0 to stable/10.6 is vulnerable to a Denial of Service (DoS) attack due to missing input validation. An authenticated attacker can cause a DoS by supplying a crafted UPDATE message. This vulnerability affects FRRouting versions 10.0 to 10.6 and has a CVSS score of 6.5, indicating a medium severity. Defenders should prioritize verifying and applying patches for affected FRRouting versions and conduct inventory checks to identify potentially affected systems.
Defensive priority
Defenders should prioritize verifying and applying patches for FRRouting versions 10.0 to 10.6. Inventory checks and monitoring for suspicious UPDATE messages are recommended.
Recommended defensive actions
- Verify and apply patches for FRRouting versions 10.0 to 10.6
- Conduct inventory checks to identify potentially affected systems
- Monitor network traffic for suspicious UPDATE messages
- Implement compensating controls to mitigate potential DoS attacks
Evidence notes
The CVE record and NVD entry provide details on the vulnerability, including its description, CVSS score, and affected versions. However, the corpus does not establish specific exploitation instances or remediation beyond patching.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-37458 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-37458
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-37458 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-37458
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://github.com/FRRouting/frr/commit/8102a8aeceb9f86fdfe1f80cd77080522bab69c8
[email protected] - Patch
-
Source reference
Unverified legacy reference
URL: https://github.com/mertsatilmaz/vulnerability-research/blob/main/advisories/CVE-2026-36365.md
[email protected] - Third Party Advisory
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.