PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-22576 Fortinet CVE debrief

CVE-2026-22576 is a storing passwords in a recoverable format vulnerability in Fortinet FortiSOAR. An authenticated remote attacker may retrieve passwords for multiple installed connectors via server address modification in connector configuration. This issue affects various versions of FortiSOAR PaaS and on-premise deployments. The vulnerability allows for potential unauthorized access to sensitive information. Defenders should assess exposure and prioritize securing connector configurations, especially for versions 7.3, 7.4, 7.5, and 7.6.

Vendor
Fortinet
Product
FortiSOAR PaaS
CVSS
MEDIUM 4.3
CISA KEV
Not listed in stored evidence
Original CVE published
2026-04-14
Original CVE updated
2026-10-26
Advisory published
2026-04-14
Advisory updated
2026-10-26

Who should care

Defenders and security teams responsible for Fortinet FortiSOAR deployments, especially those using versions 7.3, 7.4, 7.5, and 7.6, should assess exposure and prioritize securing connector configurations.

Why it matters

CVE-2026-22576 is a storing passwords in a recoverable format vulnerability in Fortinet FortiSOAR that may allow an authenticated remote attacker to retrieve passwords for multiple installed connectors. Defenders should prioritize verifying and securing connector configurations, especially for affected versions.

  • Potential unauthorized access to connector passwords
  • Need for verification of connector configuration security
  • Potential impact on incident response and password management
  • Priority for updating to fixed versions if available

Technical summary

The vulnerability allows an authenticated remote attacker to retrieve passwords for multiple installed connectors via server address modification in connector configuration. Affected versions include Fortinet FortiSOAR PaaS 7.6.0 through 7.6.4, 7.5.0 through 7.5.2, and all versions of 7.4 and 7.3 for both PaaS and on-premise deployments. The issue arises from storing passwords in a recoverable format, which could lead to unauthorized access if not properly secured. Defenders should prioritize verifying and securing connector configurations, especially for affected versions, and consider updating to fixed versions if available.

Defensive priority

Defenders should prioritize verifying and securing connector configurations, especially for versions 7.3, 7.4, 7.5, and 7.6, and consider updating to fixed versions if available.

Recommended defensive actions

  • Verify and secure connector configurations, especially for versions 7.3, 7.4, 7.5, and 7.6
  • Consider updating to fixed versions if available
  • Monitor for potential unauthorized access to connector passwords
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and NVD entry provide details on the vulnerability, affected versions, and potential impacts. However, specific exploitation details or confirmed attacks are not provided in the source corpus.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-22576 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-22576

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-22576 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-22576

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.