PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-125399 FluxionNetwork CVE debrief

CVE-2026-125399 is an OS command injection vulnerability in Fluxion before version 6.39. The vulnerability is located in the fluxion.sh target scanner, which decodes access point ESSIDs using eval after escaping only single quotes. This allows attackers within Wi-Fi range to broadcast an access point with a crafted SSID, leading to command execution as root when the operator scans or selects it.

Vendor
FluxionNetwork
Product
fluxion
CVSS
HIGH 8.6
CISA KEV
Not listed in stored evidence
Original CVE published
2026-11-10
Original CVE updated
2026-11-12
Advisory published
2026-11-10
Advisory updated
2026-11-12

Who should care

Operators of Fluxion systems, particularly those using versions prior to 6.39, should be aware of this vulnerability and take steps to mitigate it. This includes upgrading to version 6.39 or later and monitoring systems for suspicious activity.

Why it matters

CVE-2026-125399 is a high-severity OS command injection vulnerability in Fluxion before version 6.39. Operators should prioritize upgrading to version 6.39 or later and monitor systems for suspicious activity.

  • Command execution as root on the Fluxion system
  • Potential for lateral movement within the network
  • Need for immediate upgrade to version 6.39 or later
  • Verification of system logs for signs of exploitation

Technical summary

The fluxion.sh target scanner in Fluxion before version 6.39 is vulnerable to OS command injection. The scanner decodes access point ESSIDs using eval after escaping only single quotes, allowing attackers to execute commands as root by broadcasting a crafted SSID. This vulnerability can be mitigated by upgrading to version 6.39 or later and monitoring systems for suspicious activity. Operators should prioritize upgrading to version 6.39 or later to mitigate this vulnerability. In the meantime, they should monitor their systems for suspicious activity and limit access to the Fluxion system to trusted users.

Defensive priority

Operators of Fluxion should prioritize upgrading to version 6.39 or later to mitigate this vulnerability. In the meantime, they should monitor their systems for suspicious activity and limit access to the Fluxion system to trusted users.

Recommended defensive actions

  • Upgrade to Fluxion version 6.39 or later
  • Monitor systems for suspicious activity
  • Limit access to the Fluxion system to trusted users
  • Review system logs for signs of exploitation
  • Verify the integrity of the Fluxion system
  • Conduct a thorough risk assessment to identify potential vulnerabilities
  • Implement additional security measures to prevent lateral movement

Evidence notes

The CVE record and NVD entry provide details on the vulnerability, including its description, CVSS score, and affected versions. The vendor, FluxionNetwork, has released a patched version (6.39) and provided additional information through various GitHub links.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-125399 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-125399

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-125399 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-125399

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.