PatchSiren cyber security CVE debrief
CVE-2026-113800 electron CVE debrief
Electron HID and USB permission checks can be misattributed to the wrong origin due to a vulnerability in the setPermissionCheckHandler function. This issue allows apps that use HID or USB permissions and embed cross-origin iframes to grant unintended access. Developers and security teams should assess their exposure and update to fixed versions or adjust their logic accordingly. The vulnerability affects Electron applications that use HID or USB permissions and embed cross-origin iframes with allow='hid' or allow='usb'.
- Vendor
- electron
- Product
- Unknown
- CVSS
- MEDIUM 5.4
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-21
- Original CVE updated
- 2026-10-21
- Advisory published
- 2026-10-21
- Advisory updated
- 2026-10-21
Who should care
Developers and security teams responsible for Electron applications that use HID or USB permissions and embed cross-origin iframes should assess their exposure and update to fixed versions or adjust their logic accordingly.
Why it matters
CVE-2026-113800 allows unintended access to Electron applications using HID or USB permissions. Assess exposure, update to fixed versions, and adjust logic to prevent exploitation.
- Assess and update Electron applications to fixed versions to prevent unintended access.
- Review and adjust origin-based logic for HID and USB permissions.
- Avoid adding allow='hid' or allow='usb' to untrusted iframes to limit exposure.
Technical summary
In Electron, HID and USB permission checks made from an iframe were incorrectly attributed to the top-level frame's origin and details instead of the requesting frame's. This could allow apps that use setPermissionCheckHandler with origin-based logic for HID or USB and embed cross-origin iframes with allow='hid' or allow='usb' to grant unintended access. The vulnerability affects Electron applications that use HID or USB permissions and embed cross-origin iframes. Developers should review and adjust their origin-based logic for HID and USB permissions.
Defensive priority
Assess exposure in Electron applications using setPermissionCheckHandler with origin-based logic for HID or USB and embedding cross-origin iframes with allow='hid' or allow='usb'.
Recommended defensive actions
- Assess and update Electron applications to use fixed versions: 45.0.0-alpha.5, 44.3.0, 43.7.0, or 42.11.3.
- Review and adjust origin-based logic for HID and USB permissions in setPermissionCheckHandler.
- Avoid adding allow='hid' or allow='usb' to untrusted iframes.
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up.
- Review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance.
- Plan vendor-supported updates or mitigations through normal change control where exposure is confirmed.
- Check relevant monitoring, detection, and logs for exposed assets that need extra review.
Evidence notes
The source corpus provides details on the vulnerability and affected versions. Evidence of exploitation is not provided, but developers should verify their applications' exposure and update to fixed versions. The vulnerability is attributed to incorrect origin and details being used in permission checks. Limited evidence is available, and defenders should review the official advisory and CVE record for more information.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-113800 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-113800
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-113800 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-113800
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Electron: HID and USB permission checks can be attributed to the wrong origin
Unverified legacy reference
URL: https://storage.googleapis.com/osv-vulnerabilities/npm/GHSA-fw47-9c62-h3vw.json
osv_dev
-
Source reference
Unverified legacy reference
URL: https://github.com/electron/electron/security/advisories/GHSA-fw47-9c62-h3vw
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://github.com/electron/electron/pull/53656
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://github.com/electron/electron/pull/53679
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://github.com/electron/electron/pull/53688
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://github.com/electron/electron/pull/53689
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://github.com/electron/electron/pull/53736
Supplemental source
-
Source reference
Unverified legacy reference
URL: https://github.com/electron/electron/commit/22de0a3a06cfd3174fc6c59c3810ab5e1c91bf1a
Supplemental source
Methodology and review provenance