PatchSiren cyber security CVE debrief
CVE-2026-13564 Edimax CVE debrief
CVE-2026-13564 is a high-severity vulnerability in Edimax EW-7478APC. The vulnerability is caused by a stack-based buffer overflow in the formPPPoESetup POST request handler due to improper handling of the pppUserName argument. This vulnerability can be exploited remotely, and its exploit has been made public. The vendor, Edimax, has not responded to this disclosure. Affected devices should be updated with a patched firmware version as soon as possible.
- Vendor
- Edimax
- Product
- EW-7478APC
- CVSS
- HIGH 7.4
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-06-29
- Original CVE updated
- 2026-06-29
- Advisory published
- 2026-06-29
- Advisory updated
- 2026-06-29
Who should care
Network administrators and security teams responsible for Edimax EW-7478APC devices should be aware of this vulnerability. They should assess their current device inventory, check for any signs of compromise, and apply patches or mitigations as necessary. Additionally, security teams should monitor network traffic for potential exploitation attempts.
Technical summary
The vulnerability is caused by a stack-based buffer overflow in the formPPPoESetup POST request handler of Edimax EW-7478APC version 1.04. The overflow occurs when the pppUserName argument is not properly validated, allowing an attacker to inject malicious data. The CVSS score for this vulnerability is 7.4, indicating a high severity level. The vulnerability can be exploited remotely, and its exploit has been made public.
Defensive priority
High priority should be given to patching Edimax EW-7478APC devices. Network administrators should verify that their devices are running a patched firmware version and monitor network traffic for potential exploitation attempts.
Recommended defensive actions
- Apply patches or updates provided by the vendor to fix the stack-based buffer overflow vulnerability.
- Conduct a thorough inventory of Edimax EW-7478APC devices and assess their current firmware versions.
- Monitor network traffic for potential exploitation attempts and signs of compromise.
- Implement compensating controls, such as firewall rules or intrusion detection systems, to detect and prevent exploitation attempts.
- Consider replacing Edimax EW-7478APC devices with alternative products that have a better security track record.
Evidence notes
The CVE-2026-13564 vulnerability was found in Edimax EW-7478APC version 1.04. The vulnerability is caused by a stack-based buffer overflow in the formPPPoESetup POST request handler. The exploit has been made public, and the vendor has not responded to this disclosure. The CVSS score for this vulnerability is 7.4, indicating a high severity level.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-13564 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-13564
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-13564 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-13564
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://lavender-bicycle-a5a.notion.site/EDIMAX-EW-7478APC-formPPPoESetup-34b53a41781f80208e6be16a764f001c
-
Source reference
Unverified legacy reference
URL: https://vuldb.com/cve/CVE-2026-13564
-
Source reference
Unverified legacy reference
URL: https://vuldb.com/submit/844114
-
Source reference
Unverified legacy reference
URL: https://vuldb.com/vuln/374572
-
Source reference
Unverified legacy reference
URL: https://vuldb.com/vuln/374572/cti
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.