This CVE represents a mitigation bypass and incomplete fix for CVE-2025-62582, an unauthenticated remote database access vulnerability affecting DIAView projects. The original vulnerability allowed unauthenticated remote attackers to access configured databases; this new CVE indicates that previous remediation efforts were insufficient. The vulnerability carries a CVSS 3.1 score of 9.8 (Critical), reflecting network attack vector, low attack complexity, no required privileges or user interaction, and high impacts to confidentiality, integrity, and availability. The weakness is classified as CWE-321 (Use of Hard-coded Cryptographic Key). Tenable has published a security research advisory (TRA-2026-44) documenting this bypass. Organizations that applied fixes for CVE-2025-62582 should treat this as an active threat requiring immediate reassessment of their DIAView deployments.

Vendor
Delta Electronics
Product
DIAView
CVSS
CRITICAL 9.8
CISA KEV
Not listed in stored evidence
Original CVE published
2026-05-26
Original CVE updated
2026-05-27
Advisory published
2026-05-26
Advisory updated
2026-05-27

Who should care

Organizations operating DIAView SCADA/HMI systems, particularly those with database connectivity exposed to operational networks or with prior exposure to CVE-2025-62582. Industrial control system security teams, OT network defenders, and asset owners in manufacturing, energy, and critical infrastructure sectors should prioritize response.

Technical summary

CVE-2026-9642 documents a bypass of mitigations for CVE-2025-62582 in DIAView, an industrial automation platform. The vulnerability allows unauthenticated remote attackers to access configured project databases, indicating that cryptographic protections or access controls implemented in response to the prior CVE remain insufficient. The CWE-321 classification suggests hard-coded cryptographic key material contributes to the bypass. Attack complexity is low with no authentication required, enabling broad exploitation. Organizations must treat prior remediation as incomplete and pursue updated vendor guidance.

Defensive priority

critical

Recommended defensive actions

  • Review Tenable advisory TRA-2026-44 for technical details on the mitigation bypass
  • Audit DIAView deployments for exposure of database configurations to untrusted networks
  • Apply vendor-supplied patches or mitigations when available, prioritizing internet-facing systems
  • Implement network segmentation to restrict DIAView database access to authorized hosts only
  • Monitor for anomalous database connection attempts from unexpected source addresses
  • Reassess compensating controls deployed for CVE-2025-62582 as they may be insufficient

Evidence notes

CVE published 2026-05-26. Tenable advisory TRA-2026-44 serves as primary technical source. No CISA KEV entry at time of analysis. Vendor identification marked low confidence requiring review.

Official resources