PatchSiren cyber security CVE debrief
CVE-2025-62582 Delta Electronics CVE debrief
Delta Electronics DIAView contains multiple critical vulnerabilities that permit unauthenticated remote attackers to achieve full system compromise. The CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H) indicates network-exploitable, low-complexity attacks requiring no privileges or user interaction, resulting in complete confidentiality, integrity, and availability loss. The associated CWE-306 (Missing Authentication for Critical Function) suggests authentication bypass as a root cause. Affected versions span all releases prior to 4.4.0. Delta Electronics published security advisory PCSA-2026-00001 addressing CVE-2025-62581 and CVE-2025-62582. The CVE was initially published on 2026-01-16 and last modified on 2026-05-29, indicating recent updates to vulnerability details or affected product information. No known exploitation in ransomware campaigns has been documented (KEV: false).
- Vendor
- Delta Electronics
- Product
- DIAView
- CVSS
- CRITICAL 9.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-01-16
- Original CVE updated
- 2026-05-29
- Advisory published
- 2026-01-16
- Advisory updated
- 2026-05-29
Who should care
OT security teams, industrial control system operators, SCADA/HMI administrators, manufacturing security personnel, and organizations utilizing Delta Electronics DIAView for process visualization and control
Technical summary
DIAView versions prior to 4.4.0 contain missing authentication vulnerabilities (CWE-306) enabling unauthenticated network-based attacks. The critical CVSS 9.8 score reflects complete system compromise potential without user interaction. Attack vectors are network-accessible with low exploitation complexity.
Defensive priority
CRITICAL
Recommended defensive actions
- Upgrade DIAView to version 4.4.0 or later per vendor advisory
- Review network segmentation for DIAView installations to restrict unauthorized access
- Monitor for anomalous authentication attempts or unauthorized administrative actions
- Apply principle of least privilege to DIAView service accounts
- Verify backup and recovery procedures for affected SCADA/HMI systems
Evidence notes
NVD CPE confirms deltaww:diaview:*:*:*:*:*:*:*:* versions prior to 4.4.0 are vulnerable. CVSS 9.8 CRITICAL score derived from official NVD record. CWE-306 (Missing Authentication for Critical Function) identified as secondary weakness.
Official resources
-
CVE-2025-62582 CVE record
CVE.org
-
CVE-2025-62582 NVD detail
NVD
-
Source item URL
nvd_modified
-
Source reference
759f5e80-c8e1-4224-bead-956d7b33c98b
Vendor-disclosed via Delta Electronics security advisory PCSA-2026-00001