PatchSiren cyber security CVE debrief
CVE-2024-12834 Delta Electronics CVE debrief
Delta Electronics DRASimuCAD contains a type confusion vulnerability that allows specially crafted files to supply incorrect data types during file opening operations. The vulnerability, published on January 9, 2025, and updated on January 16, 2025, affects DRASimuCAD versions 1.02.00.00 and earlier. The CVSS 3.1 score of 7.8 (HIGH) reflects local attack vector with low attack complexity, no privileges required, but user interaction needed. Successful exploitation could result in high impacts to confidentiality, integrity, and availability. Delta Electronics released a patch on January 16, 2025, which requires the base version 1.02.00.00 to be installed first.
- Vendor
- Delta Electronics
- Product
- DRASimuCAD
- CVSS
- HIGH 7.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-01-09
- Original CVE updated
- 2025-01-16
- Advisory published
- 2025-01-09
- Advisory updated
- 2025-01-16
Who should care
Organizations using Delta Electronics DRASimuCAD for industrial robot simulation and programming, particularly in manufacturing, automotive, and electronics assembly environments. Security teams responsible for OT/ICS asset protection and engineering workstation hardening should prioritize this patch.
Technical summary
The vulnerability stems from insufficient input validation when DRASimuCAD opens files. The application expects specific data types but fails to properly validate or reject malformed input, accepting data of incorrect types from attacker-controlled files. This type confusion weakness can lead to memory corruption and arbitrary code execution in the context of the application. The attack requires local access with user interaction (opening a malicious file), making it suitable for targeted attacks against engineering workstations through social engineering or compromised file distribution channels.
Defensive priority
HIGH
Recommended defensive actions
- Apply Delta Electronics patch for DRASimuCAD (requires base version 1.02.00.00 installed first)
- Avoid opening untrusted DRASimuCAD project files from unknown sources
- Implement application whitelisting to restrict unauthorized software execution
- Isolate engineering workstations from business networks and internet exposure
- Use secure remote access methods (VPN) when remote maintenance is required
- Review and apply CISA ICS recommended practices for defense-in-depth
Evidence notes
Vulnerability confirmed through CISA ICS advisory ICSA-25-010-03 with vendor acknowledgment. Patch availability confirmed in Update A revision dated 2025-01-16.
Sources and references
Verified primary and authoritative sources
-
CVE-2024-12834 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2024-12834
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2024-12834 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2024-12834
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-010-03.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-010-03
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B
Reference
Methodology and review provenance