CVE-2026-79943 Dell CVE debrief

CVE-2026-79943 Improper Validation of Certificate with Host Mismatch vulnerability in Dell SCG 5.0 Appliance and Dell SCG 5.0 Application allows unauthenticated attackers to bypass protection mechanisms. Dell has released security updates for affected versions. Affected product deployments should review and apply these updates to prevent potential protection mechanism bypass. This vulnerability has a Medium severity level and requires immediate attention from administrators and security teams.

Vendor
Dell
Product
Secure Connect Gateway 5.0 - Application
CVSS
MEDIUM 4.8
CISA KEV
Not listed in stored evidence
Original CVE published
2026-09-07
Original CVE updated
2026-09-07
Advisory published
2026-09-07
Advisory updated
2026-09-07

Who should care

Administrators and security teams responsible for Dell SCG 5.0 Appliance and Dell SCG 5.0 Application deployments should review and apply security updates to prevent potential protection mechanism bypass.

Why it matters

CVE-2026-79943 is a Medium-severity vulnerability in Dell SCG 5.0 Appliance and Dell SCG 5.0 Application that allows unauthenticated attackers to bypass protection mechanisms. Administrators and security teams should review and apply Dell security updates, verify certificate validation mechanisms, and monitor for unauthorized access attempts.

  • Potential bypass of protection mechanisms
  • Increased risk of unauthorized access
  • Need for verification of certificate validation mechanisms
  • Priority for applying Dell security updates

Technical summary

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00 contain an Improper Validation of Certificate with Host Mismatch vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to protection mechanism bypass. The vulnerability has a CVSS score of 4.8 and a Medium severity level. Administrators and security teams should review and apply Dell security updates to prevent potential protection mechanism bypass.

Defensive priority

Medium

Recommended defensive actions

  • Review and apply Dell security updates for affected SCG 5.0 Appliance and SCG 5.0 Application versions
  • Verify certificate validation mechanisms in Dell SCG deployments
  • Monitor for unauthorized access attempts on Dell SCG systems
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
  • Review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance
  • Plan vendor-supported updates or mitigations through normal change control where exposure is confirmed
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review

Evidence notes

The CVE record and NVD entry provide details on the vulnerability. Dell has released a security update for affected versions. The vulnerability allows unauthenticated attackers with remote access to potentially exploit it, leading to protection mechanism bypass. Evidence is limited to public CVE and NVD sources; further verification is recommended.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-79943 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-79943

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-79943 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-79943

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Methodology and review provenance