PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-79695 Dell CVE debrief

Dell Secure Connect Gateway (SCG) versions prior to 5.36.00.16 and 5.36.00.00 are vulnerable to a Data Amplification issue, a form of Improper Handling of Highly Compressed Data. An unauthenticated attacker with remote access could exploit this, leading to denial of service. This issue affects Dell SCG deployments, which require immediate attention to prevent potential disruptions. Defenders should assess exposure and apply patches to mitigate this vulnerability. The CVE record and vendor advisory provide further details on affected versions and patching guidance.

Vendor
Dell
Product
Secure Connect Gateway 5.0 - Application
CVSS
HIGH 7.3
CISA KEV
Not listed in stored evidence
Original CVE published
2026-09-09
Original CVE updated
2026-09-14
Advisory published
2026-09-09
Advisory updated
2026-09-14

Who should care

Defenders responsible for Dell Secure Connect Gateway deployments should assess exposure and apply patches to prevent potential denial of service attacks. This includes reviewing current versions, identifying affected systems, and prioritizing patching for critical deployments. Additionally, defenders should monitor for potential attacks and review compensating controls for exposed systems.

Why it matters

Defenders should care about CVE-2026-79695 because it affects Dell Secure Connect Gateway, allowing unauthenticated remote attackers to cause denial of service. Affected versions require patching to prevent exposure.

  • Potential denial of service for affected deployments

Technical summary

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00 contain an Improper Handling of Highly Compressed Data (Data Amplification) vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability, leading to denial of service. This vulnerability affects Dell SCG deployments, and defenders should prioritize verifying exposure and applying patches to prevent potential disruptions. The CVE record and vendor advisory provide further details on affected versions and patching guidance.

Defensive priority

Defenders should prioritize verifying exposure and applying patches due to the potential for denial of service.

Recommended defensive actions

  • Verify exposure of Dell SCG versions prior to 5.36.00.16 and 5.36.00.00
  • Apply patches to affected versions
  • Monitor for potential denial of service attacks
  • Review compensating controls for exposed systems
  • Check relevant monitoring, detection, and logs for exposed assets
  • Track exceptions and retest remediated assets
  • Review vendor guidance for additional mitigation strategies

Evidence notes

The CVE record and NVD entry provide details on the vulnerability, including affected versions and potential impacts. Vendor advisory is available from Dell, which provides guidance on patching and mitigation. However, specific details on the vulnerability's exploitation and affected scope are limited. Defenders should verify exposure and apply patches according to vendor guidance. Additional information may be necessary to fully understand the vulnerability's impact.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-79695 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-79695

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-79695 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-79695

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source reference

    Unverified legacy reference

    URL: https://www.dell.com/support/kbdoc/en-in/000503426/dsa-2026-382-security-update-for-dell-secure-connect-gateway-virtual-edition-multiple-vulnerabilities

    [email protected] - Vendor Advisory

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.