Dell Unisphere for PowerMax vApp versions 9.2.4.x contain a Command Injection vulnerability. A high-privileged attacker with remote access could exploit this, potentially leading to remote execution. This vulnerability requires immediate attention, and IT administrators should assess exposure, review access controls, and prioritize patching to version 9.2.4.23 or later. Monitoring for suspicious activity is recommended to prevent potential remote execution attempts. The CVE record and vendor advisory DSA-2026-447 provide details on the vulnerability.
- Vendor
- Dell
- Product
- Unisphere for PowerMax vApp
- CVSS
- MEDIUM 6.6
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-14
- Original CVE updated
- 2026-10-15
- Advisory published
- 2026-10-14
- Advisory updated
- 2026-10-15
Who should care
IT administrators and security teams responsible for Dell Unisphere for PowerMax vApp systems should assess exposure and prioritize patching to version 9.2.4.23 or later. High-privileged user access controls need review, and monitoring for suspicious activity is recommended to prevent potential remote execution attempts.
Why it matters
CVE-2026-101216 is a Command Injection vulnerability in Dell Unisphere for PowerMax vApp versions 9.2.4.x. High-privileged attackers with remote access could exploit this for potential remote execution. IT administrators and security teams should assess exposure, review access controls, prioritize patching to version 9.2.4.23 or later, and monitor for suspicious activity.
- Potential remote execution requires immediate attention
- High-privileged user access controls need review
- Patching to version 9.2.4.23 or later is necessary
- Monitoring for suspicious activity is recommended
Technical summary
Dell Unisphere for PowerMax vApp versions 9.2.4.x are vulnerable to a Command Injection vulnerability. A high-privileged attacker with remote access could potentially exploit this vulnerability, leading to remote execution. The vulnerability is caused by improper neutralization of special elements used in a command. IT administrators and security teams should assess exposure and prioritize patching to version 9.2.4.23 or later. The CVE record and vendor advisory DSA-2026-447 provide details on the vulnerability. Affected product deployments should be identified, and owners assigned for follow-up.
Defensive priority
Assess exposure and prioritize patching for Unisphere for PowerMax vApp versions 9.2.4.x.
Recommended defensive actions
- Inventory Unisphere for PowerMax vApp versions 9.2.4.x for potential exposure
- Prioritize patching to version 9.2.4.23 or later
- Monitor for potential remote execution attempts
- Review and update access controls for high-privileged users
- Assess exposure and prioritize patching for Unisphere for PowerMax vApp versions 9.2.4.x
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
Evidence notes
The CVE record and NVD entry provide details on the Command Injection vulnerability in Dell Unisphere for PowerMax vApp. Vendor advisory DSA-2026-447 is available. A high-privileged attacker with remote access could potentially exploit this vulnerability, leading to remote execution. IT administrators and security teams should assess exposure and prioritize patching to version 9.2.4.23 or later.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-101216 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-101216
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-101216 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-101216
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
CVE-2026-101216
Unverified legacy reference
URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/101xxx/CVE-2026-101216.json
cve_program_cvelist_v5
-
Source reference
Unverified legacy reference
URL: https://www.dell.com/support/kbdoc/en-us/000515611/dsa-2026-447-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-solutions-enabler-and-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilities
Supplemental source - vendor-advisory
Methodology and review provenance