CVE-2025-24843 affects Dario Health’s USB-C Blood Glucose Monitoring System Starter Kit Android application. CISA’s advisory describes an insecure file retrieval process that could allow file manipulation and impact product stability and the confidentiality, integrity, authenticity, and attestation of stored data. The supplied CVSS vector indicates a local attack with no user interaction and low integrity/availability impact. Dario Health’s stated mitigation is to update the Android application to the latest version from trusted sources; the advisory also recommends avoiding rooted/jailbroken devices and public untrusted networks.
- Vendor
- Dario Health
- Product
- USB-C Blood Glucose Monitoring System Starter Kit Android Applications
- CVSS
- MEDIUM 5.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-02-27
- Original CVE updated
- 2025-02-27
- Advisory published
- 2025-02-27
- Advisory updated
- 2025-02-27
Who should care
Users and administrators of the Dario Health Android mobile application, especially environments where the app is used to support blood glucose monitoring workflows. Security teams responsible for mobile device hygiene, app update management, and trusted-app distribution should also pay attention.
Technical summary
The advisory identifies an insecure file retrieval process in the Dario Health Android application. The stated consequence is potential file manipulation, which can affect stability and data protections for stored information. The supplied CVSS 3.1 vector is AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L (5.1, medium), indicating local attack conditions with limited integrity and availability impact. The source corpus does not provide deeper exploitation details beyond the advisory’s high-level description.
Defensive priority
Medium. Prioritize updating the Dario Health Android application to the latest vendor version, since the advisory indicates a local attack path and potential impact to stored data integrity and application stability.
Recommended defensive actions
- Update the Dario Health Android mobile application to the latest version using trusted sources only.
- Follow Dario Health’s guidance to avoid rooted or jailbroken devices.
- Avoid using the application over public or otherwise untrusted networks.
- If you need product-specific guidance, contact Dario Health directly through its published contact channel.
- Treat the advisory as a mobile application integrity issue and verify that deployed app versions are current.
Evidence notes
The source advisory (ICSMA-25-058-01) states: "Insecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data." The remediations section recommends updating the Android mobile application to the latest version, using trusted sources, avoiding rooted/jailbroken devices, and avoiding public untrusted networks. The supplied CVSS vector is CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L, and the advisory was initially published on 2025-02-27 UTC.
Sources and references
Verified primary and authoritative sources
-
CVE-2025-24843 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2025-24843
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2025-24843 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2025-24843
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsma-25-058-01.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-058-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/topics/industrial-control-systems
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.