CVE-2026-7865 Crestron Electronics CVE debrief

A hidden console command in Crestron devices is vulnerable to command injection when control characters are passed to its second argument. This vulnerability allows attackers with authenticated access to the SSH console to run underlying OS commands. The vulnerability was discovered by Eugene Lim, a third-party researcher. The CVE record was published on 2026-05-05T16:16:19.730Z and has not been modified since then.

Vendor
Crestron Electronics
Product
Touchpanels (x60/x70)
CVSS
HIGH 7.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-05-05
Original CVE updated
2026-07-24
Advisory published
2026-05-05
Advisory updated
2026-07-24

Who should care

Organizations using Crestron devices, particularly those with SSH console access, should be aware of this vulnerability and take steps to mitigate it. This includes reviewing the official advisory and CVE record, and implementing compensating controls such as restricting SSH access and monitoring for suspicious activity.

Technical summary

The vulnerability exists in a hidden console command in Crestron devices that fails to properly handle control characters in its second argument, allowing for command injection. This could enable an attacker with authenticated SSH console access to execute arbitrary OS commands. The vulnerability was discovered by Eugene Lim, a third-party researcher. To verify the vulnerability, defenders should review the official advisory and CVE record. The CVE record was published on 2026-05-05T16:16:19.730Z and last modified on 2026-07-24T08:10:00.150Z. The NVD entry is currently Awaiting Analysis. Organizations should review compensating controls such as restricting SSH access and monitoring for suspicious activity.

Defensive priority

High

Recommended defensive actions

  • Inventory Crestron devices with SSH console access and prioritize patching
  • Implement compensating controls such as restricting SSH access and monitoring for suspicious activity
  • Verify vendor remediation and apply patches as available
  • Review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance
  • Plan vendor-supported updates or mitigations through normal change control where exposure is confirmed
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented

Evidence notes

The CVE record was published on 2026-05-05T16:16:19.730Z and last modified on 2026-07-24T08:10:00.150Z. The NVD entry is currently Awaiting Analysis. This information is based on the NVD entry and the CVE record. The vulnerability affects Crestron devices, which may be used in various environments. To verify the vulnerability, defenders should review the official advisory and CVE record.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-7865 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-7865

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-7865 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-7865

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source reference

    Unverified legacy reference

    URL: https://www.crestron.com/Software-Firmware/Firmware/Touchpanels/TS-770-TS-1070-TSS-770-TSS-1070-TSW-570/3-003-0015-001

    25b0b659-c4b4-483f-aecb-067757d23ef3

  • Source reference

    Unverified legacy reference

    URL: https://www.crestron.com/release_notes/tsw-xx70_3.003.0015.001_release_notes.pdf

    25b0b659-c4b4-483f-aecb-067757d23ef3

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.