CVE-2025-54754 Cognex CVE debrief
CVE-2025-54754 is a high-severity Cognex industrial-vision issue disclosed by CISA on 2025-09-18. According to the advisory, an attacker with adjacent access and no authentication can recover a hard-coded password embedded in publicly available software. That password can then be used to decrypt sensitive network traffic, putting Cognex device communications at risk. CISA’s advisory covers In-Sight Explorer and multiple In-Sight product families, including the 2000, 7000, 8000, and 9000 series.
- Vendor
- Cognex
- Product
- In-Sight 2000 series
- CVSS
- HIGH 8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-09-18
- Original CVE updated
- 2025-09-18
- Advisory published
- 2025-09-18
- Advisory updated
- 2025-09-18
Who should care
OT/ICS operators, plant engineers, system integrators, and network/security teams responsible for Cognex In-Sight deployments, especially environments that still rely on In-Sight Explorer-based or otherwise legacy vision systems.
Technical summary
The issue is a secret exposure / hard-coded credential problem in publicly available software associated with Cognex In-Sight devices. Exploitation requires adjacent network access but no authentication. Once the embedded password is obtained, it can be used to decrypt sensitive network traffic associated with the device, which elevates exposure of industrial data in transit. The supplied advisory also notes that In-Sight Explorer-based vision systems are legacy products not intended for new applications and points owners toward next-generation In-Sight Vision Suite-based systems.
Defensive priority
High. The attack does not require authentication, and the access boundary is only adjacent rather than remote, which makes network segmentation and local trust assumptions especially important. Because the impact includes decryption of sensitive traffic, defenders should treat this as a confidentiality-focused OT exposure that may also undermine broader trust in device communications.
Recommended defensive actions
- Inventory all Cognex In-Sight Explorer and In-Sight camera firmware deployments, including 2000/7000/8000/9000 series systems.
- Restrict adjacent network access to affected devices with segmentation, access controls, and tight Layer 2/Layer 3 boundaries.
- Prioritize migration away from In-Sight Explorer-based legacy systems to next-generation In-Sight Vision Suite-based products, such as In-Sight 2800, In-Sight 3800, and In-Sight 8900 series embedded cameras.
- Review whether any sensitive traffic associated with affected devices is exposed on shared or untrusted internal networks.
- Apply CISA and vendor guidance for industrial-control-system defense-in-depth and monitoring.
- Track the CISA advisory and vendor communications for any additional remediation guidance or product-specific updates.
Evidence notes
Primary evidence comes from the CISA CSAF advisory ICSA-25-261-06, published 2025-09-18, which states that an adjacent, unauthenticated attacker can retrieve a hard-coded password embedded in publicly available software and use it to decrypt sensitive network traffic. The advisory lists the affected product families as In-Sight 2000, 7000, 8000, 9000, and In-Sight Explorer. The supplied remediation notes that In-Sight Explorer-based vision systems are legacy products and recommends moving to next-generation In-Sight Vision Suite-based systems.
Official resources
-
CVE-2025-54754 CVE record
CVE.org
-
CVE-2025-54754 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
CISA published the advisory and CSAF record on 2025-09-18 as the initial publication. This brief uses the CVE/advisory publication date provided in the source timeline, not generation time.