PatchSiren cyber security CVE debrief
CVE-2026-35226 CODESYS CVE debrief
A high-severity out-of-bounds write vulnerability exists in the CODESYS PROFINET Controller, allowing an unauthenticated attacker on the same network segment to send malformed PROFINET communication data that triggers an exception in the affected PLC application, resulting in a controlled stop of the PLC application. The vulnerability has a CVSS score of 7.1 and is considered high severity. Defenders should assess exposure and prioritize verification and patching to prevent potential disruptions.
- Vendor
- CODESYS
- Product
- CODESYS PROFINET
- CVSS
- HIGH 7.1
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-07-29
- Original CVE updated
- 2026-10-23
- Advisory published
- 2026-07-29
- Advisory updated
- 2026-10-23
Who should care
Defenders responsible for industrial control systems and networks, particularly those using CODESYS PROFINET Controller, should assess exposure and prioritize verification and patching
Why it matters
CVE-2026-35226 is a high-severity vulnerability in CODESYS PROFINET Controller that allows unauthenticated attackers to trigger PLC application exceptions, potentially disrupting industrial control systems and networks.
- Verify and apply patches or mitigations to prevent potential disruptions
- Assess exposure in industrial control systems and networks to prioritize remediation
- Monitor PLC application logs for exceptions and controlled stops to detect potential attacks
Technical summary
The CODESYS PROFINET Controller is vulnerable to an out-of-bounds write attack, allowing an unauthenticated attacker to send malformed PROFINET communication data that triggers an exception in the affected PLC application, resulting in a controlled stop. The vulnerability has a CVSS score of 7.1 and is considered high severity. Defenders should prioritize verifying and applying patches or mitigations provided by the vendor, and assess exposure in industrial control systems and networks to prevent potential disruptions.
Defensive priority
Defenders should prioritize verifying and applying patches or mitigations provided by the vendor, and assess exposure in industrial control systems and networks.
Recommended defensive actions
- Verify and apply patches or mitigations provided by the vendor
- Assess exposure in industrial control systems and networks
- Monitor PLC application logs for exceptions and controlled stops
- Review compensating controls for exposed systems while remediation is scheduled and verified
- Check relevant monitoring, detection, and logs for exposed assets that need extra review
- Track exceptions, retest remediated assets, and close the item only after evidence is documented
- Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up
Evidence notes
The CVE record and NVD entry provide details on the vulnerability, but additional information on affected versions, exploitation, and remediation is limited. The CODESYS PROFINET Controller is a widely used component in industrial control systems, and defenders should verify the affected scope and apply patches or mitigations provided by the vendor. The official CVE Program record and NVD detail page offer source-provided CVE metadata and vulnerability assessment.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-35226 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-35226
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-35226 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-35226
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://www.certvde.com/en/advisories/VDE-2026-041/
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.