PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-76465 Cisco CVE debrief

A critical vulnerability exists in Cisco Nexus 3000 and 9000 Series Switches due to improper validation of MPLS echo-request packets, allowing unauthenticated remote attackers to execute arbitrary code with root privileges or cause a denial of service condition. This vulnerability, tracked as CVE-2026-76465, affects multiple versions of Cisco NX-OS Software and requires immediate attention from network administrators and cybersecurity teams. The vulnerability is confirmed by official sources, including Cisco and the CVE Program, and details on affected versions can be found in their advisories.

Vendor
Cisco
Product
Cisco NX-OS Software
CVSS
CRITICAL 9.8
CISA KEV
Not listed in stored evidence
Original CVE published
2026-10-07
Original CVE updated
2026-10-07
Advisory published
2026-10-07
Advisory updated
2026-10-07

Who should care

Network administrators, cybersecurity teams, and IT professionals responsible for managing and securing Cisco Nexus 3000 and 9000 Series Switches should be aware of this vulnerability and take immediate action to patch or mitigate affected systems.

Why it matters

This critical vulnerability in Cisco Nexus 3000 and 9000 Series Switches requires immediate attention from network administrators and cybersecurity teams to prevent potential remote code execution and denial of service conditions. Affected systems should be patched or mitigated as soon as possible, and thorough inventory checks and compensating controls should be implemented.

  • Potential for unauthenticated remote code execution with root privileges
  • Possible denial of service condition leading to device reloads
  • Need for immediate patching and verification of affected systems
  • Potential for exploitation requires verification from official sources

Technical summary

The vulnerability exists in the MPLS Operation, Administration, and Maintenance (OAM) feature of Cisco NX-OS Software for Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches. An unauthenticated, remote attacker could exploit this vulnerability by sending a crafted MPLS echo-request packet to an IP address on an affected device, potentially leading to arbitrary code execution with root privileges or a denial of service condition.

Defensive priority

High priority for immediate patching and verification of affected systems

Recommended defensive actions

  • Immediately patch affected Cisco Nexus 3000 and 9000 Series Switches with the latest NX-OS Software version
  • Verify and apply Cisco's official security advisory guidance
  • Conduct thorough inventory checks to identify and prioritize affected systems
  • Implement compensating controls, such as network segmentation or access restrictions, if patching is not immediately feasible
  • Review relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The vulnerability is confirmed in multiple versions of Cisco NX-OS Software running on Cisco Nexus 3000 and 9000 Series Switches. Official sources, including Cisco and the CVE Program, confirm the vulnerability and provide details on affected versions.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-76465 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-76465

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-76465 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-76465

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.