CVE-2025-30052 CGM CVE debrief

The CGM CLININET rsyncd service is vulnerable to authentication bypass via IP spoofing. An attacker can edit files on the affected system by spoofing an allowed IP address. This vulnerability was confirmed to affect versions up to 2026.MS3. Defenders should assess exposure and prioritize verification of affected versions and implementation of IP spoofing mitigations. The vulnerability allows unauthorized access due to weak IP-based authentication. Affected systems may be open to further exploitation if not properly secured.

Vendor
CGM
Product
CGM CLININET
CVSS
HIGH 8.8
CISA KEV
Not listed in stored evidence
Original CVE published
2026-10-23
Original CVE updated
2026-10-28
Advisory published
2026-10-23
Advisory updated
2026-10-28

Who should care

Defenders responsible for CGM CLININET systems should assess exposure and prioritize verification of affected versions and implementation of IP spoofing mitigations. Security teams need to review the vulnerability details and coordinate with system administrators to ensure proper mitigation. Operators of CGM CLININET systems should verify their versions and implement necessary security measures. Vulnerability management teams should track this issue and  

Why it matters

The CGM CLININET rsyncd service is vulnerable to authentication bypass via IP spoofing, allowing an attacker to edit files on the affected system. Defenders should prioritize verifying the affected versions and implementing IP spoofing mitigations.

  • An attacker could edit files on the affected system by spoofing an allowed IP address.
  • Defenders need to verify the affected versions of CGM CLININET and implement IP spoofing mitigations.
  • The vulnerability could be used to gain unauthorized access to the system.

Technical summary

The rsyncd service of the CGM CLININET is vulnerable to authentication bypass via IP spoofing. Access is granted based solely on the client's source IP address. An attacker able to spoof an allowed IP address can bypass this check and gain the ability to edit files on the affected system. The vulnerability was confirmed to affect versions up to 2026.MS3, but later versions may also be vulnerable. This weakness in authentication can lead to unauthorized access and potential further exploitation if not properly addressed.

Defensive priority

Defenders should prioritize verifying the affected versions of CGM CLININET and implementing IP spoofing mitigations.

Recommended defensive actions

  • Verify the version of CGM CLININET and check if it is affected by the vulnerability
  • Implement IP spoofing mitigations, such as IP address filtering or authentication mechanisms
  • Monitor system logs for suspicious activity
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE Program record and NVD vulnerability detail page provide official information about the vulnerability. The source item and supplemental sources offer additional context. Evidence is limited to public sources and may not reflect the full scope of affected systems or potential impacts. Defenders should verify the affected versions of CGM CLININET and implement IP spoofing mitigations. The vulnerability was confirmed in versions up to 2026.MS3, but later versions may also be vulnerable.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-30052 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-30052

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-30052 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-30052

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Authentication Bypass via IP Spoofing in CGM CLININET rsyncd

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2025/30xxx/CVE-2025-30052.json

    cve_program_cvelist_v5

  • Source reference

    Unverified legacy reference

    URL: https://cert.pl/en/posts/2026/10/CVE-2025-30043/

    Supplemental source - third-party-advisory

  • Source reference

    Unverified legacy reference

    URL: https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html

    Supplemental source - product

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.