CVE-2025-39686 covers a Linux kernel comedi subsystem bug in insn_rw_emulate_bits(), where the default emulation path for INSN_READ and INSN_WRITE only handled a single sample even when callers requested multiple samples via insn->n. In the advisory text, that mismatch could trigger KASAN kernel-infoleak errors when insn->n was greater than 1, and the scoring reflects a local issue with high availability impact. CISA’s CSAF advisory maps the issue to Siemens SIMATIC CN 4100 versions before 5.0 and cites a vendor fix to update to V5.0 or later.
- Vendor
- Cert Portal
- Product
- Siemens SIMATIC CN 4100 vers:intdot/<5.0
- CVSS
- MEDIUM 5.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-05-12
- Original CVE updated
- 2026-05-14
- Advisory published
- 2026-05-12
- Advisory updated
- 2026-05-14
Who should care
Administrators and operators of Siemens SIMATIC CN 4100 appliances covered by ICSA-26-134-10, especially systems running versions earlier than 5.0. Linux/embedded platform teams should also review any deployment that relies on the comedi subsystem’s INSN_BITS-to-INSN_READ/WRITE emulation path.
Technical summary
The vulnerable helper insn_rw_emulate_bits() is used as a fallback when a subdevice implements INSN_BITS but not INSN_READ or INSN_WRITE. The bug is that the helper only emulated one sample, while the instruction contract allows multiple samples through insn->n. For INSN_READ, the comedi core may copy insn->n samples back to user space, so under multi-sample requests the helper’s incomplete handling could surface uninitialized data handling problems and KASAN kernel-infoleak warnings. The advisory’s CVSS vector rates the issue as local, low-complexity, low-privilege, and availability-high.
Defensive priority
Moderate to high for affected Siemens/embedded Linux environments: plan patching in the next normal maintenance window, and accelerate if the device is exposed to routine local user access or if the comedi path is in active use.
Recommended defensive actions
- Update affected Siemens SIMATIC CN 4100 systems to V5.0 or later, per the Siemens remediation guidance.
- Verify whether the device or embedded image is actually affected by the advisory mapping before scheduling maintenance.
- Inventory Linux kernel builds and confirm whether the comedi subsystem is present and used on deployed systems.
- Treat any local-privilege access on affected systems as higher risk until remediation is complete.
- Use the official Siemens and CISA advisory references to validate product applicability and remediation steps.
Evidence notes
Primary evidence comes from the CISA CSAF advisory ICSA-26-134-10 and the linked Siemens ProductCERT advisory SSA-032379, both of which describe the comedi insn_rw_emulate_bits() sample-count mismatch and the vendor remediation to update to V5.0 or later. The supplied source also provides the CVSS v3.1 vector AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H. The vendor/product mapping in the source is marked low confidence and needs review, so product applicability should be confirmed against the vendor advisory before broad rollout.
Official resources
-
CVE-2025-39686 CVE record
CVE.org
-
CVE-2025-39686 NVD detail
NVD
-
Source item URL
cisa_csaf
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
-
Source reference
Reference
Published 2026-05-12; CISA republication noted 2026-05-14. This debrief uses the CVE publication timeline supplied in the source corpus.