PatchSiren

PatchSiren cyber security CVE debrief

CVE-2025-5965 Centreon CVE debrief

A high-severity OS Command Injection vulnerability exists in Centreon Infra Monitoring's backup configuration setup, allowing users with high privileges to inject custom instructions. This issue affects multiple versions of Centreon Infra Monitoring, including 25.10.0 before 25.10.2, 24.10.0 before 24.10.15, and 24.04.0 before 24.04.19. The vulnerability has a CVSS score of 7.2 and is classified as HIGH. Centreon administrators and security teams should be aware of this vulnerability and take necessary actions to mitigate or patch it.

Vendor
Centreon
Product
Infra Monitoring
CVSS
HIGH 7.2
CISA KEV
Not listed in stored evidence
Original CVE published
2026-01-05
Original CVE updated
2026-09-30
Advisory published
2026-01-05
Advisory updated
2026-09-30

Who should care

Centreon administrators, security teams, and IT professionals responsible for Centreon Infra Monitoring systems should be aware of this vulnerability and take necessary actions to mitigate or patch it.

Why it matters

This high-severity vulnerability requires immediate attention from Centreon administrators and security teams to prevent potential OS command injection attacks and protect their systems.

  • Potential OS command injection attacks
  • Elevation of privileges for high-privilege users
  • Possible disruption of Centreon Infra Monitoring services

Technical summary

The CVE-2025-5965 vulnerability is an OS Command Injection issue in Centreon Infra Monitoring's backup configuration setup. It allows users with high privileges to concatenate custom instructions to the backup setup, potentially leading to OS command injection attacks. The vulnerability affects multiple versions of Centreon Infra Monitoring, including 25.10.0 before 25.10.2, 24.10.0 before 24.10.15, and 24.04.0 before 24.04.19. Centreon administrators and security teams should prioritize patching or mitigating this vulnerability to prevent potential OS command injection attacks.

Defensive priority

Centreon administrators and security teams should prioritize patching or mitigating this vulnerability to prevent potential OS command injection attacks.

Recommended defensive actions

  • Apply patches or updates to affected Centreon Infra Monitoring versions
  • Restrict access to backup configuration setup for high-privilege users
  • Monitor for suspicious activity or anomalies in Centreon Infra Monitoring systems
  • Review compensating controls for exposed systems while remediation is scheduled and verified
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up

Evidence notes

The CVE record and NVD entry provide details on the vulnerability, including its CVSS score of 7.2 and affected versions. However, there is limited information on potential exploitation or victim impact.

Sources and references

Verified primary and authoritative sources

  • CVE-2025-5965 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2025-5965

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2025-5965 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2025-5965

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Source reference

    Unverified legacy reference

    URL: https://github.com/centreon/centreon/releases

    bd4443e6-1eef-43f3-9886-25fc9ceeaae7 - Release Notes

  • Source reference

    Unverified legacy reference

    URL: https://thewatch.centreon.com/latest-security-bulletins-64/cve-2025-5965-centreon-web-high-severity-5362

    bd4443e6-1eef-43f3-9886-25fc9ceeaae7 - Patch, Vendor Advisory

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.