PatchSiren cyber security CVE debrief
CVE-2026-18769 Beckhoff Automation CVE debrief
A local low privileged attacker can move arbitrary physical memory content via TcRouter.sys because of exposed IOCTL function calls resulting in a full compromise of the affected devices. This vulnerability, CVE-2026-18769, is a high-severity issue that allows for local privilege escalation and potential arbitrary physical memory relocation. Defenders and administrators of Beckhoff Automation's TcRouter.sys and TwinCAT.XAR.Base.KM products should assess exposure and prioritize updates to mitigate the vulnerability. The affected products include TcRouter.sys for Windows on x64 and x86, and TwinCAT.XAR.Base.KM. It is essential to verify system configurations and inventory for exposed
- Vendor
- Beckhoff Automation
- Product
- TcRouter.sys for Windows on x64 3.1.0.2364
- CVSS
- HIGH 8.5
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-11-11
- Original CVE updated
- 2026-11-16
- Advisory published
- 2026-11-11
- Advisory updated
- 2026-11-16
Who should care
Defenders and administrators of Beckhoff Automation's TcRouter.sys and TwinCAT.XAR.Base.KM products should assess exposure and prioritize updates to mitigate the vulnerability.
Why it matters
CVE-2026-18769 is a high-severity vulnerability in TcRouter.sys that allows local low privileged attackers to relocate arbitrary physical memory content, potentially leading to a full compromise of affected devices. Defenders and administrators of Beckhoff Automation's TcRouter.sys and TwinCAT.XAR.Base.KM products should assess exposure and prioritize updates to mitigate the vulnerability.
- Local privilege escalation to compromise affected devices
- Potential for arbitrary physical memory relocation
- Need for verification of system configurations and inventory
- Priority for updating TcRouter.sys to version 3.1.0.2365 or later
Technical summary
The vulnerability in TcRouter.sys allows a local low privileged attacker to move arbitrary physical memory content due to exposed IOCTL function calls. This can result in a full compromise of the affected devices. The affected products include TcRouter.sys for Windows on x64 and x86, and TwinCAT.XAR.Base.KM.
Defensive priority
High priority for updating TcRouter.sys to version 3.1.0.2365 or later and assessing exposure of Beckhoff Automation products TwinCAT.XAR.Base.KM and TcRouter.sys
Recommended defensive actions
- Update TcRouter.sys to version 3.1.0.2365 or later
- Assess exposure of Beckhoff Automation products TwinCAT.XAR.Base.KM and TcRouter.sys
- Verify system configurations and inventory for affected versions
Evidence notes
The CVE record and source item provide details on the vulnerability in TcRouter.sys, allowing local relocation of arbitrary physical memory. The affected products and versions are listed, including TcRouter.sys for Windows on x64 and x86, and TwinCAT.XAR.Base.KM.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-18769 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-18769
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-18769 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-18769
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
A local low privileged attacker can move arbitrary physical memory content via TcRouter.sys...
Unverified legacy reference
URL: https://github.com/advisories/GHSA-x59q-qhqr-ghwc
github_advisory_database
-
Source reference
Unverified legacy reference
URL: https://www.certvde.com/en/advisories/VDE-2026-087
Supplemental source
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.