PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-97180 ASSA ABLOY Seawing CVE debrief

A critical vulnerability was found in ASSA ABLOY Seawing SC-1000 WebConfig, allowing remote command injection via HTTP requests due to insufficient input sanitization. This issue, tracked as CVE-2026-97180, enables a privileged attacker to execute arbitrary commands as the root user. The vulnerability was fixed in version 1.5.14. Affected systems may require immediate attention to prevent exploitation. Defenders must assess exposure and implement patches or mitigations to prevent system compromise.

Vendor
ASSA ABLOY Seawing
Product
SC-1000 WebConfig
CVSS
CRITICAL 9.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-11-25
Original CVE updated
2026-11-25
Advisory published
2026-11-25
Advisory updated
2026-11-25

Who should care

Defenders responsible for SC-1000 WebConfig systems, especially those accessible over the internet, should assess exposure and implement mitigations. Operators of affected systems must prioritize verifying exposure and ensuring systems are updated to version 1.5.14 or later. Vulnerability management and security teams should review the supplied official advisory or CVE record to validate affected scope, severity, and vendor guidance.

Why it matters

CVE-2026-97180 is a critical vulnerability in ASSA ABLOY Seawing SC-1000 WebConfig that allows remote command injection. Defenders must assess exposure and implement patches or mitigations to prevent system compromise.

  • Remote command injection allows attackers to execute arbitrary commands as root.
  • Successful exploitation could lead to complete system compromise.
  • Defenders must verify exposure and implement patches or mitigations.
  • Affected systems may require immediate attention to prevent exploitation.

Technical summary

The ASSA ABLOY Seawing SC-1000 WebConfig is vulnerable to remote command injection via HTTP requests. A privileged attacker can inject shell metacharacters in the server parameter, resulting in arbitrary command execution as the root user on the operating system. This issue was fixed in version 1.5.14. The vulnerability allows attackers to execute arbitrary commands as the root user, potentially leading to complete system compromise. Defenders must verify exposure and implement patches or mitigations to prevent system compromise.

Defensive priority

Defenders should prioritize verifying exposure of SC-1000 WebConfig systems, especially those accessible over the internet, and ensure they are updated to version 1.5.14 or later.

Recommended defensive actions

  • Verify SC-1000 WebConfig systems for exposure, especially those accessible over the internet.
  • Ensure SC-1000 WebConfig systems are updated to version 1.5.14 or later.
  • Monitor SC-1000 WebConfig systems for suspicious activity.
  • Review compensating controls for exposed systems while remediation is scheduled and verified.
  • Check relevant monitoring, detection, and logs for exposed assets that need extra review.
  • Track exceptions, retest remediated assets, and close the item only after evidence is documented.
  • Confirm whether affected product deployments exist in managed environments and assign an owner for follow-up.

Evidence notes

The CVE record and source item provide details on the vulnerability, its impact, and the fix. However, additional information from other sources may be necessary to fully assess exposure and implement effective mitigations.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-97180 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-97180

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-97180 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-97180

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • Command Injection in ASSA ABLOY Seawing SC-1000 WebConfig

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/CVEProject/cvelistV5/main/cves/2026/97xxx/CVE-2026-97180.json

    cve_program_cvelist_v5

  • Source reference

    Unverified legacy reference

    URL: https://cert.pl/en/posts/2026/11/CVE-2026-97180

    Supplemental source - third-party-advisory

  • Source reference

    Unverified legacy reference

    URL: https://www.seawing.eu/hu/en/products/access-control/vezerlk1/sc-1000-termekcsalad

    Supplemental source - product

  • Source reference

    Unverified legacy reference

    URL: https://www.seawing.eu/hu/en/about-us/product-security-security-advisory

    Supplemental source - vendor-advisory

Methodology and review provenance