PatchSiren cyber security CVE debrief
CVE-2026-111458 adulau CVE debrief
CVE-2026-111458 is a heap-based buffer overflow vulnerability in the fanx_fingerprint function of ssldump, caused by a miscalculation in the allocation size for formatting FAN/1 X.509 certificate fingerprints. This vulnerability allows an attacker who can supply a crafted pcap file to a user running ssldump with FAN/1 fingerprinting enabled to trigger a denial of service or potentially arbitrary code execution.
- Vendor
- adulau
- Product
- ssldump
- CVSS
- MEDIUM 6.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2026-10-16
- Original CVE updated
- 2026-10-16
- Advisory published
- 2026-10-16
- Advisory updated
- 2026-10-16
Who should care
Defenders responsible for systems and applications using ssldump, especially those processing untrusted input, should assess exposure and prioritize verification and remediation efforts.
Why it matters
CVE-2026-111458 is a heap-based buffer overflow vulnerability in ssldump that allows for denial of service or potential arbitrary code execution. Defenders should prioritize verifying ssldump versions and configurations, especially in environments where untrusted input is processed.
- Denial of service through a crash
- Potential arbitrary code execution in the context of the user running ssldump
- Verification of ssldump versions and configurations is required
Technical summary
The fanx_fingerprint function in ssl/sslxprint.c of ssldump allocates a heap buffer for formatting FAN/1 X.509 certificate fingerprints. The allocation size is computed as strlen(b64) + strlen(hex) + 31, but the format string contains 33 fixed characters in addition to the two variable-length fields and a null terminator, requiring strlen(b64) + strlen(hex) + 34 bytes. This miscalculation results in a 3-byte heap-based buffer overflow on every invocation of the function with valid inputs.
Defensive priority
Defenders should prioritize verifying ssldump versions and configurations, especially in environments where untrusted input is processed.
Recommended defensive actions
- Verify ssldump versions and configurations to ensure they are up-to-date and properly secured.
- Restrict input to ssldump to only trusted sources.
- Monitor for and apply patches or updates provided by the vendor.
- Perform a thorough review of ssldump configurations and environments to identify potential exposure.
- Implement additional monitoring and logging to detect potential exploitation attempts.
- Conduct a thorough asset inventory to identify systems and applications using ssldump.
- Review and update incident response plans to include procedures for responding to potential exploitation of this vulnerability.
Evidence notes
The CVE record and NVD entry provide details on the vulnerability, including its description and CVSS score. However, specific details about affected versions and patches are not provided in the corpus.
Sources and references
Verified primary and authoritative sources
-
CVE-2026-111458 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2026-111458
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2026-111458 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2026-111458
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source reference
Unverified legacy reference
URL: https://github.com/adulau/ssldump/commit/8ad55683cc0186600c085d33be5a5b627db78467
5a6e4751-2f3f-4070-9419-94fb35b644e8
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.