PatchSiren

PatchSiren cyber security CVE debrief

CVE-2026-15953 ABB CVE debrief

A vulnerability exists in the processing of PCM600 project archives files in ABB Protection and Control IED Manager PCM600. Insufficient validation of archive entry paths may permit path traversal during extraction, potentially allowing files to be written to locations outside the intended extraction directory. This could lead to unauthorized file writes and potential system compromise. Defenders responsible for industrial control systems, particularly those using ABB Protection and Control IED Manager PCM600, should assess exposure and prioritize verification and mitigation.

Vendor
ABB
Product
Protection and Control IED Manager PCM600
CVSS
MEDIUM 5
CISA KEV
Not listed in stored evidence
Original CVE published
2026-10-01
Original CVE updated
2026-10-01
Advisory published
2026-10-01
Advisory updated
2026-10-01

Who should care

Defenders responsible for industrial control systems, particularly those using ABB Protection and Control IED Manager PCM600, should assess exposure and prioritize verification and mitigation.

Why it matters

Defenders should prioritize verifying and applying mitigations due to potential path traversal during extraction in ABB Protection and Control IED Manager PCM600.

  • Path traversal during extraction may allow files to be written to locations outside the intended extraction directory
  • Potential for unauthorized file writes outside the intended directory
  • Need for verification of system configuration and monitoring

Technical summary

The vulnerability exists in the processing of PCM600 project archives files in ABB Protection and Control IED Manager PCM600. Insufficient validation of archive entry paths may permit path traversal during extraction, potentially allowing files to be written to locations outside the intended extraction directory. This could lead to unauthorized file writes and potential system compromise. The vulnerability is related to the handling of archive files and the potential for path traversal attacks. Defenders should prioritize verifying and applying mitigations from ABB.

Defensive priority

Defenders should prioritize verifying and applying the provided workarounds and mitigations from ABB, as well as ensuring that the system is properly configured and monitored.

Recommended defensive actions

  • Verify and apply the provided workarounds and mitigations from ABB
  • Ensure that the system is properly configured and monitored
  • Review and implement the recommended practices for industrial control systems
  • Conduct a thorough review of system configurations and asset inventory
  • Implement compensating controls for exposed systems while remediation is scheduled and verified
  • Monitor relevant logs and detection systems for signs of exploitation
  • Track exceptions and retest remediated assets to ensure vulnerability closure

Evidence notes

The vulnerability is described in the CISA CSAF file and CVE Program record. The source item provides details on the affected product and potential impact. Evidence is limited to publicly available information and may not reflect the full scope of affected systems or potential impacts. Defenders should verify system configurations and monitor for potential exploitation attempts. Additional information may be necessary to fully understand the vulnerability and its implications.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-15953 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-15953

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-15953 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-15953

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • ABB Protection and Control IED Manager PCM600

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-274-03.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-274-03

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014

    Supplemental source

Methodology and review provenance