CVE-2026-15952 ABB CVE debrief

A vulnerability exists in the Scheduler Service installed with ABB Protection and Control IED Manager PCM600. The service executes under the LocalSystem account while permissions are granted to standard PCM600 users through membership in the local users group. An attacker with local access and valid user credentials may exploit this vulnerability to elevate privileges and obtain control of the affected host.

Vendor
ABB
Product
Protection and Control IED Manager PCM600
CVSS
MEDIUM 6.4
CISA KEV
Not listed in stored evidence
Original CVE published
2026-10-01
Original CVE updated
2026-10-01
Advisory published
2026-10-01
Advisory updated
2026-10-01

Who should care

Defenders responsible for industrial control systems, particularly those using ABB Protection and Control IED Manager PCM600, should assess exposure and prioritize verification of affected systems.

Why it matters

Defenders should prioritize verifying exposed systems, restricting local access, and ensuring proper privilege management to prevent potential privilege escalation and control of affected hosts.

  • Verify exposed systems and restrict local access
  • Ensure proper privilege management
  • Monitor for suspicious activity

Technical summary

The Scheduler Service in ABB Protection and Control IED Manager PCM600 executes under the LocalSystem account, but permissions are granted to standard PCM600 users. An attacker with local access and valid user credentials may exploit this vulnerability to elevate privileges and obtain control of the affected host. This could allow an attacker to gain unauthorized access and control of the system, potentially leading to further malicious activity. Defenders should prioritize verifying exposed systems, restricting local access, and ensuring proper privilege management.

Defensive priority

Defenders should prioritize verifying exposed systems, restricting local access, and ensuring proper privilege management.

Recommended defensive actions

  • Verify exposed systems and restrict local access
  • Ensure proper privilege management
  • Monitor for suspicious activity
  • Review compensating controls for exposed systems
  • Check relevant monitoring, detection, and logs for exposed assets
  • Track exceptions, retest remediated assets
  • Plan vendor-supported updates or mitigations through normal change control

Evidence notes

The CVE record and source item provide details on the vulnerability, but evidence of exploitation or affected versions is limited. Defenders should verify exposed systems, restrict local access, and ensure proper privilege management. Limited evidence suggests potential for privilege escalation and control of affected hosts. Further verification is required to confirm affected scope and severity.

Sources and references

Verified primary and authoritative sources

  • CVE-2026-15952 CVE Program record

    Publisher, destination, and source semantics verified

    URL: https://www.cve.org/CVERecord?id=CVE-2026-15952

    CVE Program - Official CVE Program record with source-provided CVE metadata.

  • CVE-2026-15952 NVD vulnerability detail

    Publisher, destination, and source semantics verified

    URL: https://nvd.nist.gov/vuln/detail/CVE-2026-15952

    NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.

Supplemental references

  • ABB Protection and Control IED Manager PCM600

    Unverified legacy reference

    URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2026/icsa-26-274-03.json

    cisa_csaf

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/news-events/ics-advisories/icsa-26-274-03

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/resources-tools/resources/ics-recommended-practices

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/topics/industrial-control-systems

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/sites/default/files/publications/emailscams0905.pdf

    Supplemental source

  • Source reference

    Unverified legacy reference

    URL: https://www.cisa.gov/uscert/ncas/tips/ST04-014

    Supplemental source

Methodology and review provenance

AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.