CVE-2022-37434 ABB CVE debrief
CVE-2022-37434 is a zlib flaw in inflate() that can trigger a heap-based buffer over-read or buffer overflow when processing a large gzip header extra field. In the supplied CISA advisory, ABB maps the issue to ABB M2M Gateway ARM600 firmware versions 4.1.2 through 5.0.3 and ABB M2M Gateway SW versions 5.0.1 through 5.0.3. The vendor description says an authenticated attacker could potentially reveal sensitive information or cause denial of service.
- Vendor
- ABB
- Product
- ABB M2M Gateway ARM600
- CVSS
- HIGH 8.8
- CISA KEV
- Not listed in stored evidence
- Original CVE published
- 2025-04-07
- Original CVE updated
- 2025-04-07
- Advisory published
- 2025-04-07
- Advisory updated
- 2025-04-07
Who should care
Operators, administrators, and security teams responsible for ABB ARM600 / ABB M2M Gateway deployments, especially where the device is reachable from untrusted networks or processes externally supplied compressed data.
Technical summary
The underlying issue is in zlib through 1.2.12 and affects inflate() in inflate.c when handling a large gzip header extra field. The resulting memory-safety failure can manifest as a heap-based buffer over-read or buffer overflow. Per the supplied advisory, ABB product exposure covers ARM600 firmware 4.1.2 <= 5.0.3 and ABB M2M Gateway SW 5.0.1 <= 5.0.3. The CVSS vector supplied is AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H, indicating network-reachable impact with low attack complexity and required low privileges.
Defensive priority
High. Prioritize if the ABB ARM600 or related SW is deployed in environments that accept untrusted inputs or are internet-facing, because the vulnerability can affect confidentiality, integrity, and availability.
Recommended defensive actions
- Reduce exposure to untrusted networks: avoid exposing system components to the internet; if internet access is necessary, expose only the VPN port.
- Use a private cellular APN where possible so remote traffic does not traverse the public internet.
- Place any internet-terminated connectivity in a DMZ and segregate it from other networks with a firewall.
- Apply strict firewall allowlisting and block all non-required ports and protocols.
- Change default credentials to strong, non-reused passwords and restrict administrator/root use to tasks that require it.
- Keep supporting PCs and engineering systems updated; virus-scan configuration PCs and transferred firmware/configuration files before introducing them to the OT environment.
- Maintain and validate backups for configurations and applicable system components, and store backups securely with role-based access control.
- Use continuous monitoring and intrusion detection/prevention where feasible, and follow ABB cyber security deployment guidance and user manuals for hardening and lifecycle practices.
Evidence notes
The vulnerability summary comes from the supplied CISA CSAF advisory content and its mirrored references. The advisory ties CVE-2022-37434 to ABB M2M Gateway ARM600 and ABB M2M Gateway SW, with the affected version ranges explicitly listed in the source item metadata. The remediation guidance in the source item is focused on exposure reduction, network segmentation, credential hygiene, monitoring, backups, and hardening; no fixed version or patch instruction is stated in the provided corpus.
Sources and references
Verified primary and authoritative sources
-
CVE-2022-37434 CVE Program record
Publisher, destination, and source semantics verified
URL: https://www.cve.org/CVERecord?id=CVE-2022-37434
CVE Program - Official CVE Program record with source-provided CVE metadata.
-
CVE-2022-37434 NVD vulnerability detail
Publisher, destination, and source semantics verified
URL: https://nvd.nist.gov/vuln/detail/CVE-2022-37434
NIST National Vulnerability Database - Official NIST NVD detail page and source-specific vulnerability assessment.
Supplemental references
-
Source item URL
Unverified legacy reference
URL: https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2025/icsa-25-105-08.json
cisa_csaf
-
Source reference
Unverified legacy reference
URL: https://library.e.abb.com/public/0498e4c0babd46aa9243aedd6f99c375/ARM600_user_758861_ENk.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://library.e.abb.com/public/ffab1a14a42646c6adee38fc3de61dad/Arctic_csdepl_758860_ENf.pdf
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/news-events/ics-advisories/icsa-25-105-08
Reference
-
Source reference
Unverified legacy reference
URL: https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01
Reference
Methodology and review provenance
AI-assisted synthesis based on stored public vulnerability evidence. System validation, approval state, and publication status do not by themselves establish human review of this revision. PatchSiren helps prioritize defensive review and does not prove exposure or remediation on any system.